In May 1998 the CEOs of five European companies (AT&S, Fuba, Philips, Schweizer and STP), all members of the DRT (Directors Round Table), established by the chairman of the VdL, formed a working group with the aim of developing design rules for HDI boards (Table I and Figure 1).

Table IDesign rules for HDI cards (high density interconnection cards).All values are minimum values. High standard (not every company can fulfil all characteristics)

SymbolDescriptionStandardHigh standard
ALinewidth outerlayer0.125mm0.100mm
ALinewidth outerlayer Cu thickness < 25µm0.125mm0.100-0.075mm
BSpacing outerlayer0.125mm0.100mm
BSpacing outerlayer Cu thickness < 25µm0.125mm0.100-0.75mm
CLinewidth innerlayer Cu< 20µm0.100mm0.075mm
DSpacing innerlayer Cu< 20µm0.100mm0.075mm
EMircrovia holesize0.125mm0.100-0.075mm
FMicrovia landing pad0.30mm0.25mm
GMicrovia pad0.30mm0.25mm
HDrill size buried holeMax 0.30mm0.20mm
I1Pad size buried hole outerlayer0.50mm0.50-0.40mm
I2Pad size buried hole innerlayer0.70mm0.55mm
JDrill size plated through hole0.30mm0.20mm
K1Pad six plated through hole outerlayer0.55mm0.5-0.40mm
K2Pad size plated through hole innerlayer0.70mm0.55mm
LL/E (aspect ratio)microvia¾ 1¾ 1
MMin core thickness power/power0.100mm0.075mm
MMin core thickness signal/signal0.150mm0.100-0.075mm
NCore thickness(buried-multilayer)Min 0.40mm Min 0.30mm
  Max 0.80mmMax 1.4mm
 Copper thickness plated through hole15µm13µm
 Copper thickness buried hole15µm13µm
 Copper thickness microvia10µm8µm
 Basis materialsFR4FR4 Tg > 160°C
 Material for HDI-layerRCC, FR4 liquid dielectricumRCC, FR4 liquid
   dielectricum, with
   higher TG
 Number of HDI-layer1 of both sides2 of both sides
 Board constructionSymmetrical Symmetrical

Figure 1 Dimensions for constructing HDI cards

These design rules are intended to offer a common standard for microvia technologies. Designers employing this common standard will now be able to source boards from a variety of European manufacturers adhering to the new criteria.

The group decided to establish fundamental design rules for the Standard HDI. These rules reflect the capabilities of each member of the working group. In addition, the group has established a second column of "high standard" design rules.

Companies requiring copies of these special design rules should contact any of the member companies in the working group.

Future updates for both sets of rules are likely.

Book-to-bill

The VdL book-to-bill ratios are given in Figure 2 for December 1997-November 1998.

Figure 2 VdL-book-to-bill verhältnis (ratios) December 97-November 1998