Purpose

The purpose of this paper is to study the radiation‐natural convection interactions in a vertical divided vented channel. The effects of the surface emissivity, the vent opening position and size on the heat transfer and the flow structures inside the channel were studied.

Design/methodology/approach

The governing differential equations are solved by a finite volume method, with adopting the SIMPLER algorithm for pressure‐velocity coupling. The view factors were determined by using a boundary elements approximation and a Monte Carlo method.

Findings

The effect of the radiation exchange is very important, it increases the average hot wall Nusselt number by more than 100 per cent. The contribution of the channel wall emissivity in the heat transfer is more important than that of the plate emissivity. The average hot wall Nusselt number increases with increasing the vent opening size, only in presence of the radiation exchange, and this increase is more pronounced, particularly when the vent opening is located near the channel inlet.

Research limitations/implications

The flow is assumed to be incompressible, laminar and two dimensional. The radiative surfaces are assumed diffuse‐grey. The working fluid, air, is considered as transparent with respect to the radiation.

Practical implications

The industrial applications of this study are solar collectors, thermal building, electronic cooling, aeronautics, chemical apparatus, nuclear engineering, etc.

Originality/value

In comparison to the preceding studies, the originality of this paper is the taking into account of the radiation exchange in a vented and divided channel.

You do not currently have access to this content.
Don't already have an account? Register

Purchased this content as a guest? Enter your email address to restore access.

Please enter valid email address.
Email address must be 94 characters or fewer.
Pay-Per-View Access
$41.00
Rental

or Create an Account

Close Modal
Close Modal