Recent fire disasters in Hong Kong and other cities in China show that fire safety should receive more attention. In Hong Kong, a large number of pre‐1980 high‐rise buildings were designed according to old prescriptive building and fire codes. The fire protection measures of these buildings may not be the same as the standard in effect today, even if all fire safety items have been well maintained. Assessment of the fire safety level of these old buildings – on the basis of current prescriptive requirements – may return a conclusion that many buildings’ fire safety systems are “sub‐standard”, and the fire safety level is unacceptably low. However, whether such a conclusion is warranted, thereby triggering immediate improvement action, is debatable, because the rigid prescriptive requirements in the fire codes do not provide a holistic picture of the fire safety level in these buildings. This paper discusses the issues of site inspections for a systematic approach to perform the fire safety ranking for multi‐storey buildings.
Article navigation
Case Report|
May 01 2003
Issues of site inspections for fire safety ranking of multi‐storey buildings Available to Purchase
S.M. Lo;
S.M. Lo
Associate Professor, Department of Building and Construction, City University of Hong Kong, Hong Kong.
Search for other works by this author on:
W.Y. Cheng
W.Y. Cheng
Instructor, Department of Building and Construction, City University of Hong Kong, Hong Kong.
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 1758-6844
Print ISSN: 0263-080X
© MCB UP Limited
2003
Structural Survey (2003) 21 (2): 79–86.
Citation
Lo S, Cheng W (2003), "Issues of site inspections for fire safety ranking of multi‐storey buildings". Structural Survey, Vol. 21 No. 2 pp. 79–86, doi: https://doi.org/10.1108/02630800310479070
Download citation file:
357
Views
Suggested Reading
A building safety inspection system for fire safety issues in existing buildings
Structural Survey (December,1998)
Guidance on flame retardant systems
Facilities (May,2000)
Home inspector assessing
Structural Survey (August,2006)
How Indicators Can Perform for Hazard and Risk Management in Risk Assessments of Food Premises
British Food Journal (December,1994)
Some European systems for regulation and control of private design and construction with particular reference to fire safety
Structural Survey (January,1991)
Related Chapters
Comparison of bridge management practice in England and France
Bridge Management 5: Inspection, maintenance, assessment and repair: Proceedings of the 5th International Conference on Bridge Management, organized by the University of Surrey, 11–13 April 2005
Introduction
DESIGNERS’ GUIDE TO EUROCODE 3: DESIGN OF STEEL BUILDINGS: EN 1993-1-1, -1-3 and -1-8
General
DESIGNERS’ GUIDE TO EUROCODE 3: DESIGN OF STEEL BUILDINGS: EN 1993-1-1, -1-3 and -1-8
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
