Purpose

This paper introduces a novel multi-setup merging method and assesses its performance using simulated response data from a Finite Element (FE) model of a five-storey frame and experimental data from a cantilever beam tested in a laboratory setting.

Design/methodology/approach

In the research conducted at the Central Building Research Institute (CBRI) in Roorkee, India, a cantilever beam was examined in a laboratory setting. The study successfully extracted the modal properties of the multi-storey building using the merging technique. Identified frequencies and mode shapes provide valuable insights into the building's dynamic behavior, which is essential for structural analysis and assessment. The sensor layout and data merging approach allowed for the capture of relevant vibration modes despite the limited number of sensors, demonstrating the effectiveness of the methodology.

Findings

The results show that reducing the number of sensors can impact the accuracy of the mode shapes. It is recommended to use a minimum of 8 sensor locations (every two floors) for the building under study to obtain reliable benchmark results for further evaluation, periodic monitoring, and damage identification.

Originality/value

The results demonstrate that the developed algorithm can improve the system identification process and streamline data handling. Furthermore, the proposed method is successfully applied to analyze the modal properties of a multi-storey building.

Licensed re-use rights only
You do not currently have access to this content.
Don't already have an account? Register

Purchased this content as a guest? Enter your email address to restore access.

Please enter valid email address.
Email address must be 94 characters or fewer.
Pay-Per-View Access
$41.00
Rental

or Create an Account

Close Modal
Close Modal