Purpose

Considering the industrial site environment and installation requirements, the straight-beam ultrasound probe with easy installation and good coupling agent adaptability is adopted to replace the traditional water immersion focusing probe for film thickness measurement in cylindrical roller bearings. The straight-beam probe has a large echo receiving range, which will result in measurement regions overlapping and bring about large measurement errors. In this paper, an improved measurement method for film thickness of cylindrical roller bearing with the straight-beam probe is developed.

Design/methodology/approach

An improved method is proposed to enhance the spatial resolution of the straight-beam probe. By introducing a correction coefficient based on the percentage of the effective measurement area, the method improves the measuring accuracy successfully.

Findings

The experimental results demonstrate that the lubricant-film thickness can be measured to reasonable accuracy by this method and have a better agreement with the theoretical film thickness solutions.

Originality/value

This paper used analytical method and model that is helpful for the improvement of the spatial resolution, which has great influence on the measuring accuracy, is mainly determined by the echo reflection area size of the ultrasound transducer.