This paper presents a case study of an economical intervention on an early prestressed post-tensioned concrete structure. Built in 1960, a 60 m span concrete railway bridge at Clabecq in Belgium had a simply supported two-cell box girder. It was post-tensioned with one of the last applications in Belgium of the Blaton–Magnel ‘sandwich’ system. The cables were external to the concrete and only protected from corrosion by cement grout. Maintenance inspections in the 1990s revealed that corrosion of the tendons was so severe that the future safety of the bridge was compromised. The owner decided to replace all existing cables with new tendons placed in high-density polyethylene ducts, with each tendon composed of 15 monostrands. This paper describes the assessment of the existing structure, attempts to estimate the residual pre-stressing force and the design and implementation of the repair. It also discusses problems encountered and lessons learned.
Article navigation
September 2014
Research Article|
July 28 2014
A case study of replacement of external post-tensioning cables
Yves Rammer, MSCE;
Yves Rammer, MSCE
1
Professor, Department of Building, Architecture and Town Planning, Université Libre de Bruxelles, Brussels, Belgium
Search for other works by this author on:
Bernard Espion, MSCE, PhD
Bernard Espion, MSCE, PhD
2
Professor, Department of Building, Architecture and Town Planning, Université Libre de Bruxelles, Brussels, Belgium
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
June 19 2013
Accepted:
June 24 2014
Online ISSN: 1751-7664
Print ISSN: 1478-4637
ICE Publishing: All rights reserved
2014
Proceedings of the Institution of Civil Engineers - Bridge Engineering (2014) 167 (3): 183–192.
Article history
Received:
June 19 2013
Accepted:
June 24 2014
Citation
Rammer Y, Espion B (2014), "A case study of replacement of external post-tensioning cables". Proceedings of the Institution of Civil Engineers - Bridge Engineering, Vol. 167 No. 3 pp. 183–192, doi: https://doi.org/10.1680/bren.13.00019
Download citation file:
New and popular articles
Suggested Reading
Design of the Dubai Metro light rail viaducts—superstructure
Proceedings of the Institution of Civil Engineers - Bridge Engineering (June,2009)
Design of the Dubai Metro light rail viaducts—substructure
Proceedings of the Institution of Civil Engineers - Bridge Engineering (June,2009)
Simulation of self-centring fibre-reinforced concrete columns
Proceedings of the Institution of Civil Engineers - Engineering and Computational Mechanics (June,2008)
Deep embedment of FRP for concrete shear strengthening
Proceedings of the Institution of Civil Engineers - Structures and Buildings (October,2009)
Numerical study of seismic response of irregular multi-frame reinforced concrete bridges
Proceedings of the Institution of Civil Engineers - Structures and Buildings (February,2020)
Related Chapters
INTERNATIONAL DEVELOPMENTS IN THE FIELD OF AGEING MANAGEMENT OF NUCLEAR POWER INFRASTRUCTURE
Role of Concrete in Nuclear Facilities
FIELD TRIALS ON COVERCRETE MONITORING SENSORS: A TEMPERATURE CORRECTION PROTOCOL FOR CONDUCTIVITY MEASUREMENTS
Innovations and Developments In Concrete Materials And Construction: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 9–11 September 2002
CRITERIA FOR AND PREDICTION OF LIMIT STATES OF DEGRADATION OF REINFORCED CONCRETE STRUCTURES
Role of Concrete in Nuclear Facilities
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
