Titanium (Ti)-based materials are favourable for biomedical implant applications because of their unique biocompatibility, good corrosion resistance and moderate overall mechanical properties. Furthermore, amorphous titanium-based metallic glasses may take a decent share of the market as a result of their excellent properties. Developing low-modulus titanium-based metallic glasses is of both scientific and practical interests. In this study, the authors have analysed more than 40 different types of titanium-based metallic glasses and introduced two modified parameters that are based on a molecular orbital approach but are better in the prediction of the Young’s modulus of metal implants, which should be about 30 MPa. Alloying elements are categorised and compared accordingly. Zirconium (Zr), hafnium (Hf), niobium (Nb), tantalum (Ta), tin (Sn) and molybdenum (Mo) are proposed to be effective in designing low-Young’s-modulus biomedical titanium-based metallic glasses.
Article navigation
5 April 2019
Research Article|
February 15 2019
A novel approach to achieving a low Young’s modulus in titanium-based metallic glasses
Jia-Peng Luo;
Jia-Peng Luo
Postgraduate student
Southern University of Science and Technology, Shenzhen, China; Harbin Institute of Technology, Harbin, China
Search for other works by this author on:
Xiao Jia;
Xiao Jia
Postgraduate student
Southern University of Science and Technology, Shenzhen, China
Search for other works by this author on:
Dong-Lai Zheng;
Dong-Lai Zheng
Postgraduate student
Southern University of Science and Technology, Shenzhen, China; Harbin Institute of Technology, Harbin, China
Search for other works by this author on:
Gang Wang;
Gang Wang
Professor
Shanghai University, Shanghai, China
Search for other works by this author on:
Jian-Fei Sun;
Harbin Institute of Technology, Harbin, China
(corresponding author: jfsun@hit.edu.cn)
Search for other works by this author on:
Ming Yan
Ming Yan
Associate Professor
Southern University of Science and Technology, Shenzhen, China
Search for other works by this author on:
(corresponding author: jfsun@hit.edu.cn)
Publisher: Emerald Publishing
Received:
April 17 2016
Accepted:
December 19 2018
Online ISSN: 2046-0155
Print ISSN: 2046-0147
ICE Publishing: All rights reserved
2019
Emerging Materials Research (2019) 8 (1): 22–28.
Article history
Received:
April 17 2016
Accepted:
December 19 2018
Citation
Luo J, Jia X, Zheng D, Wang G, Sun J, Yan M (2019), "A novel approach to achieving a low Young’s modulus in titanium-based metallic glasses". Emerging Materials Research, Vol. 8 No. 1 pp. 22–28, doi: https://doi.org/10.1680/jemmr.16.00098
Download citation file:
New and popular articles
Suggested Reading
AC impedance and dielectric studies of biopolymer electrolytes based on I-carrageenan
Green Materials (September,2021)
Monte Carlo simulation of a waste soda–lime–silica glass system containing Sb2O3 for gamma-ray shielding
Emerging Materials Research (December,2020)
Enhancing reactivity and properties of fly-ash-based solid-form geopolymer via ball-milling
Emerging Materials Research (December,2019)
Electron beam effects in Ge–Se thin films and resistance change memory devices
Emerging Materials Research (June,2016)
Characterization of Nd(Tb)–Fe–B-based exchange-spring nanocomposite magnets
Emerging Materials Research (May,2019)
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.