The authors regret that the following errors appeared in this paper when it was published in Proceedings of the Institution of Civil Engineers – Engineering and Computational Mechanics 165(2): 131–145.
In section 2 on p. 132, in the sentence ‘In the experiment described here, the inner cylinder was filled with salt stratified water at room temperature (25°C) with a buoyancy frequency of N ∼ 0·44/s', the buoyancy frequency should be N ∼ 0·66/s.
In section 3.3 on p. 135, N ∼ 0·44/s should read N ∼ 0·66/s.
Throughout the paper, the units for salinity should be ppm, not g/l.
Table 2, presented on p. 139, is incorrect and is a repeat of Table 1. The correct Table 2 is published here.
Quantitative analysis of salinity and temperature for different grids
| Salinity | |||||
|---|---|---|---|---|---|
| MFE: % | MFB: % | MAE: ppm | RMSE: ppm | IA | |
| Rough | 8·63 | −0·63 | 0·81 | 1·00 | 0·992 |
| Coarse | 14·14 | 4·35 | 0·83 | 1·05 | 0·991 |
| Fine | 6·72 | −0·58 | 0·47 | 0·74 | 0·996 |
| Best | 6·87 | −0·78 | 0·48 | 0·76 | 0·996 |
| Temperature | |||||
| MFE: % | MFB: % | MAE: °C | RMSE: °C | IA | |
| Rough | 9·40 | 9·39 | 3·24 | 3·64 | 0·993 |
| Coarse | 10·20 | 10·20 | 3·46 | 4·16 | 0·991 |
| Fine | 7·88 | 7·88 | 2·70 | 3·40 | 0·994 |
| Best | 7·99 | 7·99 | 2·74 | 3·44 | 0·994 |
| Salinity | |||||
|---|---|---|---|---|---|
| MFE: % | MFB: % | MAE: ppm | RMSE: ppm | IA | |
| Rough | 8·63 | −0·63 | 0·81 | 1·00 | 0·992 |
| Coarse | 14·14 | 4·35 | 0·83 | 1·05 | 0·991 |
| Fine | 6·72 | −0·58 | 0·47 | 0·74 | 0·996 |
| Best | 6·87 | −0·78 | 0·48 | 0·76 | 0·996 |
| Temperature | |||||
| MFE: % | MFB: % | MAE: °C | RMSE: °C | IA | |
| Rough | 9·40 | 9·39 | 3·24 | 3·64 | 0·993 |
| Coarse | 10·20 | 10·20 | 3·46 | 4·16 | 0·991 |
| Fine | 7·88 | 7·88 | 2·70 | 3·40 | 0·994 |
| Best | 7·99 | 7·99 | 2·74 | 3·44 | 0·994 |