The authors regret that the following errors appeared in this paper when it was published in Proceedings of the Institution of Civil Engineers – Engineering and Computational Mechanics165(2): 131–145.

In section 2 on p. 132, in the sentence ‘In the experiment described here, the inner cylinder was filled with salt stratified water at room temperature (25°C) with a buoyancy frequency of N ∼ 0·44/s', the buoyancy frequency should be N ∼ 0·66/s.

In section 3.3 on p. 135, N ∼ 0·44/s should read N ∼ 0·66/s.

Throughout the paper, the units for salinity should be ppm, not g/l.

Table 2, presented on p. 139, is incorrect and is a repeat of Table 1. The correct Table 2 is published here.

Table 2.

Quantitative analysis of salinity and temperature for different grids

Salinity
MFE: %MFB: %MAE: ppmRMSE: ppmIA
Rough8·63−0·630·811·000·992
Coarse14·144·350·831·050·991
Fine6·72−0·580·470·740·996
Best6·87−0·780·480·760·996
Temperature
 MFE: %MFB: %MAE: °CRMSE: °CIA
Rough9·409·393·243·640·993
Coarse10·2010·203·464·160·991
Fine7·887·882·703·400·994
Best7·997·992·743·440·994