A series of laboratory tests simulating installation damage was carried out on four types of woven geogrid. Relationships between index properties of the geogrids and the loss in ultimate tensile strength, strain at failure and tensile stiffness of the geogrids are presented. For the geogrids investigated, the ratio of volume of coating material to the mass of yarn (V-M ratio) plays a major role in evaluating the loss of ultimate tensile strength; that is, the amount of ultimate strength loss decreases with an increase in V-M ratio. The V-M ratio also plays a part in the stress—strain characteristics of the damaged geogrids: for a regularly coated geogrid (PET yarn + PVC coating with a relatively low V-M ratio), similar amounts of ultimate strength and strain losses were found; for a similar geogrid with a relatively high V-M ratio, the amount of ultimate strain loss was only about 50% of the ultimate strength loss. The experimental results also indicate that the losses of tensile stiffness at 2% and 5% strains seem to be governed by the types of yarn and coating material, regardless of their V-M ratio.
Article navigation
February 2006
Research Article|
February 01 2006
Investigation of installation damage of some geogrids using laboratory tests
Huang Ching-Chuan;
Huang Ching-Chuan
Professor
1
Department of Civil Engineering, National Cheng Kung University
No. 1, Ta-Hsueh Road, Tainan, Taiwan 70101
Telephone: +886 6 2757575, Telefax: +886 6 2358542
, E-mail: samhcc@mail.ncku.edu.tw
Search for other works by this author on:
Chiou Shuay-Luen
Chiou Shuay-Luen
Graduate student
2
Department of Civil Engineering, National Cheng Kung University
No. 1, Ta-Hsueh Road, Tainan, Taiwan 70101
Telephone: +886 6 2757575, Telefax: +886 6 2358542
, E-mail: n66911295@yahoo.com.tw
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
December 07 2004
Revision Received:
September 25 2005
Accepted:
October 19 2005
Online ISSN: 1751-7613
Print ISSN: 1072-6349
© 2006 Thomas Telford Ltd
2006
Geosynthetics International (2006) 13 (1): 23–35.
Article history
Received:
December 07 2004
Revision Received:
September 25 2005
Accepted:
October 19 2005
Citation
Ching-Chuan H, Shuay-Luen C (2006), "Investigation of installation damage of some geogrids using laboratory tests". Geosynthetics International, Vol. 13 No. 1 pp. 23–35, doi: https://doi.org/10.1680/gein.2006.13.1.23
Download citation file:
Suggested Reading
Pullout response of geogrids after installation
Geosynthetics International (August,2015)
Laboratory simulation of installation damage of a geogrid
Geosynthetics International (June,2006)
Evaluation of effect of backfill particle size on installation damage reduction factors for geogrids
Geosynthetics International (April,2013)
Installation damage of geogrids: influence of load intensity
Geosynthetics International (April,2007)
The Effect of Installation Damage on the Long-Term Design Strength of a Reinforcing Geosynthetic
Geosynthetics International (January,2002)
Related Chapters
Unpaved roads
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Soil–geosynthetic interaction
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Paved roads
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.