ABSTRACT: When designing a roller-compacted concrete (RCC) spillway for a reservoir, seepage-induced uplift pressures need to be considered. This case study describes the design, construction and post-construction performance of a drainage system consisting of a geocomposite drain immediately beneath a stair-stepped RCC spillway at the Loxahatchee Reservoir in western Palm Beach County, Florida, USA. The installation comprised 2.8 km of RCC and a geocomposite drain to construct the fixed-weir emergency spillway. The primary stability issue for the spillway was the development of excessive pore water pressure beneath the RCC in the event of rapid drawdown of the reservoir. Transient seepage analysis predicted that installation of the geocomposite drain would eliminate excess pore pressures beneath the RCC, and dramatically increase the factor of safety against uplift (increased from 0.5 to a value of the order of 6), preventing structural instability of the spillway. Since placing the reservoir in operation, no structural instability has been observed in the spillway. Also, the absence of excess pore pressure is predicted by post-construction transient seepage analysis using reservoir operational-stage data.
Article navigation
October 2012
Research Article|
October 01 2012
Protecting roller-compacted concrete armored emergency spillway against uplift with geocomposite drain: Loxahatchee Reservoir example
A.T. Özer;
A.T. Özer
1
Assistant Professor, Civil Engineering Department, Okan University, Tuzla Campus, 34959, Akfirat-Tuzla, Istanbul, Turkey, Telephone: +90 216 677 1630/1978, Telefax: +90 216 677 1486, E-mail: tolga.ozer@okan.edu.tr
Search for other works by this author on:
L.G. Bromwell
L.G. Bromwell
2
Principal Engineer, AMEC-BCI Engineers & Scientists Inc., 2000 E. Edgewood Drive, Suite 215, Lakeland, FL 33803, USA, Telephone: +1 863 667 2345; Telefax: +1 863 667 2662, E-mail: les.bromwell@amec.com
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 1751-7613
Print ISSN: 1072-6349
© 2012 Thomas Telford Ltd
2012
Geosynthetics International (2012) 19 (5): 324–338.
Citation
Özer A, Bromwell L (2012), "Protecting roller-compacted concrete armored emergency spillway against uplift with geocomposite drain: Loxahatchee Reservoir example". Geosynthetics International, Vol. 19 No. 5 pp. 324–338, doi: https://doi.org/10.1680/gein.12.00019
Download citation file:
New and popular articles
Suggested Reading
Use of geocomposite drain against rapid-drawdown loading for roller-compacted concrete (RCC) armored earth dam
Geosynthetics International (October,2011)
Static liquefaction behavior of short discrete carbon fiber reinforced silty sand
Geosynthetics International (September,2020)
Ultimate bearing capacity of saturated reinforced horizontal ground
Geosynthetics International (September,2015)
Effect of a soluble subgrade on leakage through a geomembrane defect
Geosynthetics International (March,2023)
Numerical investigation into the stability of earth dam slopes considering the effects of cavities
Engineering Computations (January,2020)
Related Chapters
Slope Stability Studies of Vyasi Dam Reservoir Area, Garhwal Himalaya, U. P. India
Landslides in Research, Theory and Practice: Proceedings of the 8th International Symposium on Landslides held in Cardiff on 26–30 June 2000
Past failures and design lessons
Flood Risk: Planning, Design and Management of Flood Defence Infrastructure
Paved roads
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.