ABSTRACT: This technical paper presents the results of a test pad at an operating municipal solid waste landfill that measured pressures applied to the primary geomembrane in the double composite liner system used at the site. The pressures were measured with two pressure cells placed on top of the geomembrane and covered with varying thicknesses of sandy structural fill and rounded stone, i.e. a leachate collection and removal layer stone. The pressures were applied by two types of dozers to investigate the magnitude of applied pressures and the effect of equipment on the applied pressure. In general, the results show increased pressure with decreasing cover layer thickness, increasing speed, and turning over of the pressure cells. The data can be used to estimate the minimum layer thickness to limit the pressure applied to an underlying geomembrane to a tolerable value, e.g. 41.4 kPa, and prevent geomembrane damage or puncture during construction.
Article navigation
December 2012
Research Article|
December 01 2012
Equipment pressure applied to geomembrane in composite liner system
T.D. Stark;
T.D. Stark
1
Professor of Civil and Environmental Engineering, 2217 Newmark Civil Engineering Laboratory, University of Illinois, 205 N. Mathews Ave., Urbana, IL 61801, USA, Telephone: +1 217 333 7394, Telefax: +1 217 333 9464, E-mail: tstark@illinois.edu
Search for other works by this author on:
L.F. Pazmino;
L.F. Pazmino
2
Graduate Research Assistant, Department of Civil and Environmental Engineering, 2217 Newmark Civil Engineering Laboratory, University of Illinois, 205 N. Mathews Ave., Urbana, IL 61801, USA, Telephone: +1 217 333 7394, Telefax: +1 217 333 9464, E-mail: pazmino1@uiuc.edu
Search for other works by this author on:
C.J. McDowell;
C.J. McDowell
3
Senior Project Engineer, Barton & Loguidice, 290 Elwood Davis Road, Box 3107, Syracuse, NY 13220, USA, Telephone: +1 315 457 5200, Telefax: +1 315 451 0052, E-mail: CMcDowell@bartonandloguidice.com
Search for other works by this author on:
R. Phaneuf
R. Phaneuf
4
Project Engineer, Barton & Loguidice, 290 Elwood Davis Road, Box 3107, Syracuse, NY 13220, USA, Telephone: +1 315 457 5200, Telefax: +1 315 451 0052, E-mail: RPhaneuf@bartonandloguidice.com
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
February 02 2011
Revision Received:
May 30 2012
Accepted:
May 30 2012
Online ISSN: 1751-7613
Print ISSN: 1072-6349
© 2012 Thomas Telford Ltd
2012
Geosynthetics International (2012) 19 (6): 416–425.
Article history
Received:
February 02 2011
Revision Received:
May 30 2012
Accepted:
May 30 2012
Citation
Stark T, Pazmino L, McDowell C, Phaneuf R (2012), "Equipment pressure applied to geomembrane in composite liner system". Geosynthetics International, Vol. 19 No. 6 pp. 416–425, doi: https://doi.org/10.1680/gein.12.00020
Download citation file:
New and popular articles
Suggested Reading
Corrosion and puncture resistance of aluminium foil gas membranes beneath concrete slabs
Geosynthetics International (November,2019)
Three Levels of Geomembrane Puncture Protection
Geosynthetics International (January,1995)
Natural weathering effects on white, green, and black HDPE textured GMs
Geosynthetics International (January,2025)
Laboratory testing and numerical modeling of geomembrane electrical leak detection surveys
Geosynthetics International (August,2020)
A non-destructive method for testing non-flexible dual geomembrane seams using gas permeation
Geosynthetics International (February,2006)
Related Chapters
Landfills
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Hydraulic tunnels
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Containment ponds, reservoirs and canals
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.