ABSTRACT: Damage of geosynthetics during installation processes can affect their performance, so they are typically represented in design by applying reduction factors to their tensile strength measured in the laboratory. This paper contributes to better understanding whether this is representative of the pullout response of geogrids when confined in soil. The effects of installation damage induced in field trials of two extruded geogrids and one composite with a grid structure were studied. Pullout tests were used to characterise the impact of installation damage on the soil–geosynthetic interface interaction. The coefficients of interaction were analysed to assess the impact of different parameters, including the nominal strength of the geogrids and compaction energy applied. The coefficient of interaction was affected differently by installation, depending on both the geosynthetic and the soil in contact with it. Confinement in a soil with higher friction angle was more effective in mobilising the interface strength, for both undamaged and damaged samples. The type of soil in contact with the geosynthetics was more relevant for the interface strength than the normal stresses applied in the tests. The main lesson learned from this study is that the use of results from tensile strength of damaged materials to estimate the corresponding effects on their pullout response can lead to very conservative solutions.
Article navigation
October 2015
Research Article|
August 11 2015
Pullout response of geogrids after installation Available to Purchase
M. Pinho-Lopes;
M. Pinho-Lopes
Lecturer
1Faculty of Engineering and the Environment, University of Southampton, Highfield, Southampton SO17 1BJ, UK, Telephone: +44 2380598363; Telefax: +44 2380677519; E-mail: M.Pinho-Lopes@soton.ac.uk (Corresponding author)
Search for other works by this author on:
A. M. Paula;
A. M. Paula
Adjunct Professor
2Department of Applied Mechanics, Polytechnic Institute of Bragança, Campus de Santa Apolónia, Bragança 5300-253, Portugal, Telephone: +351273303154; Telefax: +351273325405; E-mail: mpaula@ipb.pt
Search for other works by this author on:
M. L. Lopes
M. L. Lopes
Full Professor
3Department of Civil Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, s/n Porto 4200-465, Portugal, Telephone: +3515081564; Telefax: +3515081901; E-mail: lcosta@fe.up.pt
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
June 27 2014
Revision Received:
January 09 2015
Accepted:
April 14 2015
Online ISSN: 1751-7613
Print ISSN: 1072-6349
© 2015 Thomas Telford Ltd
2015
Geosynthetics International (2015) 22 (5): 339–354.
Article history
Received:
June 27 2014
Revision Received:
January 09 2015
Accepted:
April 14 2015
Citation
Pinho-Lopes M, Paula AM, Lopes ML (2015), "Pullout response of geogrids after installation". Geosynthetics International, Vol. 22 No. 5 pp. 339–354, doi: https://doi.org/10.1680/jgein.15.00016
Download citation file:
Suggested Reading
Investigation of installation damage of some geogrids using laboratory tests
Geosynthetics International (February,2006)
Evaluation of effect of backfill particle size on installation damage reduction factors for geogrids
Geosynthetics International (April,2013)
Soil–geosynthetic interaction in pullout and inclined-plane shear for two geosynthetics exhumed after installation damage
Geosynthetics International (July,2016)
Geogrid pullout behaviour according to the experimental evaluation of the active length
Geosynthetics International (December,2015)
Micro-mechanism of the interaction between sand and geogrid transverse ribs
Geosynthetics International (December,2012)
Related Chapters
Unpaved roads
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Paved roads
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Slopes – stabilisation
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
