The study estimates the lower bound values of the seismic bearing capacity of a strip footing placed on a reinforced cohesionless soil slope. The influence of slope angle, soil friction angle, horizontal seismic acceleration coefficient, depth of first reinforcement layer from the footing base and vertical spacing between two reinforcement layers was investigated. The effectiveness of using a reinforcement layer is expressed by an efficiency factor, which is the ratio of the bearing capacity factor for reinforced and unreinforced slopes. The bearing capacity increases by approximately 15 times for a few cases with a single layer reinforced slope. With the inclusion of another layer of reinforcement, this improvement is doubled. The influence of setback position of footing with respect to the slope edge is also investigated for a few representative slopes subjected to both static and seismic loading. Beyond a critical distance, the setback effect is negligible. Several design charts are presented. Stress contours are plotted to understand the failure mechanisms of unreinforced and reinforced slopes.
Article navigation
October 2019
Research Article|
October 11 2019
Seismic bearing capacity of strip footing placed on a reinforced slope
K. Halder;
K. Halder
1Research scholar, Department of Civil Engineering, Indian Institute of Technology Kharagpur, West Bengal-721302, India, E-mail: koushikhalder@iitkgp.ac.in
Search for other works by this author on:
D. Chakraborty
D. Chakraborty
2Assistant Professor, Department of Civil Engineering, Indian Institute of Technology Kharagpur, West Bengal-721302, India, E-mail: debarghya@civil.iitkgp.ac.in (corresponding author)
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
August 24 2018
Revision Received:
December 11 2018
Accepted:
May 27 2019
Online ISSN: 1751-7613
Print ISSN: 1072-6349
© 2019 Thomas Telford Ltd
2019
Geosynthetics International (2019) 26 (5): 474–484.
Article history
Received:
August 24 2018
Revision Received:
December 11 2018
Accepted:
May 27 2019
Citation
Halder K, Chakraborty D (2019), "Seismic bearing capacity of strip footing placed on a reinforced slope". Geosynthetics International, Vol. 26 No. 5 pp. 474–484, doi: https://doi.org/10.1680/jgein.19.00032
Download citation file:
New and popular articles
Suggested Reading
Load behaviour of model strip footings on reinforced transparent soils
Geosynthetics International (April,2019)
Influence of facing toe condition on the bearing capacity of full-height panel MSE walls
Geosynthetics International (March,2022)
Bearing performance of a novel caisson–plate gravity anchor
Geotechnique (June,2024)
Centrifuge model and numerical studies of strip footing on reinforced transparent soils
Geosynthetics International (August,2022)
Bearing Capacity Failure of a Trapezoidal, Geosynthetic-Reinforced Soil Wall
Geosynthetics International (January,1999)
Related Chapters
Paved roads
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Slopes – stabilisation
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
BEHAVIOUR OF SHALLOW STRIP FOUNDATIONS WITH STRUCTURAL SKIRTS RESTING ON DENSE SAND
Challenges of Concrete Construction: Volume 6, Concrete for Extreme Conditions: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 9–11 September 2002
Recommended for you