Backfill relative density can have a significant influence on the performance and stability of reinforced soil retaining walls, as reflected in the form of minimum compaction requirements in current design guidelines. However, the quantitative influence of backfill relative density on the construction and serviceability performance of reinforced soil walls has not been examined adequately. In this study, centrifuge tests were carried out on two model walls with different backfill relative densities, and their measured performances were compared against those calculated using available empirical methods. Results of the study show that maximum displacement of the model with inadequate compaction (i.e. Dr = 65%) was 30% greater than that of the Dr = 95% model and exceeded the value predicted by one of the design methods examined. The foundation pressure underneath the wall showed increased magnitudes under the facing and a nonlinear decrease with distance from the facing along the backfill. Additionally, the model with Dr = 95% developed larger reinforcement loads and mobilized soil-reinforcement interface coefficient values relative to the model with Dr = 65%.
Article navigation
October 2020
Research Article|
October 05 2020
Centrifuge study of reinforced soil walls with different backfill compaction densities Available to Purchase
P. Xu;
P. Xu
1PhD Candidate, Key Laboratory of High-Speed Railway Engineering of Ministry of Education, School of Civil Engineering, Southwest Jiaotong University, Chengdu, China, E-mail: bk20090201@my.swjtu.edu.cn
Search for other works by this author on:
K. Hatami;
K. Hatami
2Professor, School of Civil Engineering and Environmental Science, University of Oklahoma, Norman, OK, USA, E-mail: kianoosh@ou.edu (corresponding author)
Search for other works by this author on:
G. Jiang
G. Jiang
3Professor, Key Laboratory of High-Speed Railway Engineering of Ministry of Education, School of Civil Engineering, Southwest Jiaotong University, Chengdu, China, E-mail: sdxplt@gmail.com
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
June 07 2019
Revision Received:
December 15 2019
Accepted:
March 03 2020
Online ISSN: 1751-7613
Print ISSN: 1072-6349
© 2020 Thomas Telford Ltd
2020
Geosynthetics International (2020) 27 (5): 538–550.
Article history
Received:
June 07 2019
Revision Received:
December 15 2019
Accepted:
March 03 2020
Citation
Xu P, Hatami K, Jiang G (2020), "Centrifuge study of reinforced soil walls with different backfill compaction densities". Geosynthetics International, Vol. 27 No. 5 pp. 538–550, doi: https://doi.org/10.1680/jgein.20.00018
Download citation file:
Suggested Reading
Centrifuge model tests on geotextile-reinforced slopes
Geosynthetics International (December,2007)
Numerical study on the pseudostatic seismic stability of geosynthetic-reinforced soil segmental walls
Geosynthetics International (February,2026)
Shaking table study of the influence of facing on reinforced soil wall connection loads
Geosynthetics International (February,2020)
Deformation response of shored MSE walls under surcharge loading in the centrifuge
Geosynthetics International (December,2010)
Centrifuge model studies on geocomposite reinforced soil walls subjected to seepage
Geosynthetics International (July,2019)
Related Chapters
Paved roads
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Slopes – stabilisation
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Compaction and earthworks
Environmental Geotechnics, 2nd edition
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.