This paper presents a numerical method to predict soil-geotextile interface friction parameters. A strain softening model was used to simulate the relationship between shear stress and horizontal displacement at the soil-geotextile interface. Pull-out tests were performed on two types of geotextile, with different tensile stiffnesses, embedded in a granular soil. For each geotextile, pull-out tests were performed at confining pressures of 20, 50, 100, and 200 kPa. It was found that, unless breakage of the geotextile occurs, the peak pull-out force occurs after a small displacement of the free end of the geotextile. At the peak pull-out force, the maximum shear stress occurs near the free end of the geotextile while the shear stress at the loaded end is at or near a residual value. The use of an average interface friction angle overestimates pull-out resistance. The numerical technique developed in this paper provides more accurate values for soil-geotextile interface friction parameters.
Article navigation
Technical Paper|
January 01 1997
Load Transfer Mechanism in Pull-Out Tests
I.A. Alobaidi;
I.A. Alobaidi
Research Fellow
School of Civil Engineering, The University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom, Telephone: 44/121-414-5059, Telefax: 44/121-414-5059/3675
Search for other works by this author on:
D.J. Hoare;
D.J. Hoare
Senior Lecturer
School of Civil Engineering, The University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom, Telephone: 44/121-414-5059, Telefax: 44/121-414-5059/3675
Search for other works by this author on:
G.S. Ghataora
G.S. Ghataora
Lecturer
School of Civil Engineering, The University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom, Telephone: 44/121-414-5059, Telefax: 44/121-414-5059/3675
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
February 08 1997
Revision Received:
July 06 1997
Accepted:
July 21 1997
Online ISSN: 1751-7613
Print ISSN: 1072-6349
Industrial Fabrics Association International, 1801 County Road B West, Roseville, Minnesota 55113-4061, USA, Telephone: 1/612-222-2508, Telefax: 1/612-631-9334
1997
Geosynthetics International (1997) 4 (5): 509–521.
Article history
Received:
February 08 1997
Revision Received:
July 06 1997
Accepted:
July 21 1997
Citation
Alobaidi I, Hoare D, Ghataora G (1997), "Load Transfer Mechanism in Pull-Out Tests". Geosynthetics International, Vol. 4 No. 5 pp. 509–521, doi: https://doi.org/10.1680/gein.4.0104
Download citation file:
New and popular articles
Suggested Reading
Influence of anchorage angles on pull-out resistance of geotextile wrap around anchorage
Geosynthetics International (August,2018)
Nonwoven Geotextile-Sabkha and -Sand Interface Friction Characteristics Using Pull-Out Tests
Geosynthetics International (January,2001)
The Influence of Partial Clogging and Pressure on the Behaviour of Geotextiles in Drainage Systems
Geosynthetics International (January,2000)
Laboratory Survivability of Nonwoven Geotextiles on Open-Graded Crushed Aggregate
Geosynthetics International (January,1999)
Mechanical Response of Geosynthetic-Reinforced Flexible Pavements
Geosynthetics International (January,1999)
Related Chapters
IN SITU MECHANICAL DETERMINATION OF ELASTIC MODULUS OF CONCRETE
Challenges of Concrete Construction: Volume 3, Repair, Rejuvenation and Enhancement of Concrete: Proceedings of the International Seminar held at the University of Dundee, Scotland, UK on 5–6 September 2002
Soil–geosynthetic interaction
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
What Eye Movements and Facial Expressions Tell Us about User-Friendliness: Testing a Tool for Communicators and Journalists
Social Media Use in Crisis and Risk Communication: Emergencies, Concerns and Awareness
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
