Torsional ring shear and large-scale direct shear tests were conducted to investigate the shear behavior of polyvinyl chloride (PVC) geomembrane-geosynthetic interfaces. Specifically, the smooth and faille-finished sides of a 0.75 mm-thick PVC geomembrane were sheared against five different nonwoven geotextiles, a drainage composite, a geonet, and an unreinforced geosynthetic clay liner (GCL). Test results indicate that the smooth side of the PVC geomembrane yields a higher interface shear resistance than the faille-finished side due to the larger contact area and higher pliability of the smooth side. The interface shear behavior of the PVC geomembrane is compared to that of a high density polyethylene (HDPE) geomembrane and two very flexible polyethylene (VFPE) geomembranes. Faille-finished PVC geomembrane-nonwoven geotextile interfaces experience a post-peak strength loss of less than 25% at normal stresses between 100 and 400 kPa and no post-peak strength loss at normal stresses of 50 kPa and below. This behavior is attributed to the pliability of the PVC geomembrane, which enables (i) the geomembrane surface to be roughened, (ii) the other interface component to embed into the geomembrane as shearing progresses, and (iii) no texturing to be used that can damage the overlying geosynthetic. The effects of nonwoven geotextile fiber type, mass per unit area, and calendering on PVC geomembrane-nonwoven geotextile interface strength are also investigated.
Article navigation
Technical Paper|
January 01 2001
Shear Strength Characteristics of PVC Geomembrane-Geosynthetic Interfaces Available to Purchase
R.P. Hillman;
R.P. Hillman
Project Engineer
Golder Associates, Inc., 10 Chrysler, Suite B, Irvine, California 92618, USA, Telephone: 1/949-583-2700, Telefax: 1/949-583-2770, E-mail: rhillman@golder.com
Search for other works by this author on:
T.D. Stark
T.D. Stark
Professor of Civil and Environmental Engineering
2217 Newmark Civil Engineering Laboratory, University of Illinois, 205 N. Mathews Ave., Urbana, Illinois 61801, USA, Telephone: 1/217-333-7394, Telefax: 1/217-333-9464, E-mail: t-stark1@uiuc.edu
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
December 29 1999
Revision Received:
January 03 2001
Accepted:
January 04 2001
Online ISSN: 1751-7613
Print ISSN: 1072-6349
Industrial Fabrics Association International, 1801 County Road B West, Roseville, Minnesota 55113-4061, USA, Telephone: 1/612-222-2508, Telefax: 1/612-631-9334
2001
Geosynthetics International (2001) 8 (2): 135–162.
Article history
Received:
December 29 1999
Revision Received:
January 03 2001
Accepted:
January 04 2001
Citation
Hillman R, Stark T (2001), "Shear Strength Characteristics of PVC Geomembrane-Geosynthetic Interfaces". Geosynthetics International, Vol. 8 No. 2 pp. 135–162, doi: https://doi.org/10.1680/gein.8.0190
Download citation file:
Suggested Reading
Peak versus residual interface strengths for landfill liner and cover design
Geosynthetics International (December,2004)
Case history of liner veneer instability
Geosynthetics International (February,2006)
Back-analysis of a PVC geomembrane-lined pond failure
Geosynthetics International (August,2008)
Temperature-controlled interface shear testing of geosynthetics: an experimental study
Geosynthetics International (March,2026)
Lower-bound shear strength for geosynthetic clay liners in base liners
Geosynthetics International (June,2004)
Related Chapters
Clay–interface shear resistance
Selected papers on geotechnical engineering by P R Vaughan
Amtico’s Net Zero Journey So Far
Examining Net Zero: Creating Solutions for a Greener Society and Sustainable Economic Growth
Earth dams
Handbook of Geosynthetic Engineering: Geosynthetics and their applications
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
