In order to study the behaviour of a compressible layer resting on a rough rigid base, several loading tests were carried out on a large-scale model. For all the tests the compressible layer consists of dry sand with the following mean characteristics: density= 1·61 and σ = 38° (triaxial test). The load was applied to rigid footings of width B = 20, 35 and 50 cm. Several values of the ratio H/B, where H is the thickness of the compressible layer, are studied between 0·5 and 6·8. The shallow footing case is also investigated for B= 35 cm with Df/B = 0·25, 0·50 and 1·0, where Df is the depth of the footing. Special attention is paid to the influence of the parameter H/B on the bearing capacity and geometry of the failure. The experimental values obtained are compared with the theoretical and experimental results already published.
Dans le but d'étudier le comportement d'une couche compressible d'épaisseur limitée par une base rigide rugueuse, de nombreux essais de chargement ont été réalisés dans un modèle de grandes dimensions. Le matériau formant la couche compressible est un sable sec de caractéristiques moyennes: densité = 1·61 et σ = 38° (essai triaxial) pour tous les essais. Les fondations utilisées sont des semelles rigides de largeur B = 20, 35 et 50 cm. Plusieurs valeurs du rapport H/B, où H représente l'épaisseur de la couche compressible, sont étudiées, variant entre 0·5 et 6·8. Le cas semienterré est traité pour B = 35 cm avec Df/B = 0·25, 0·50 et 1·0, Df étant la profondeur de la fondation. L'influence du paramètre H/B sur la géométrie de la rupture et la capacité portante est plus particulièrement étudiée. Les résultats obtenus sont comparés dans certains cas avec les résultats théoriques et expérimentaux déjà connus.