The pressure exerted by the material stored in rectangular flexible-wall silos is investigated during filling. Tests on a large-scale steel model silo with a pyramidal hopper showed that the stress state of the material stored is influenced significantly by the wall flexibility and boundary conditions. The measured wall pressures were very different from pressures predicted by traditional theories and existing design codes. This is because most traditional theories were developed for rigid-wall circular silos and ignored the effects of interaction between stored material and structure. The causes of the observed pressure redistribution are explained.
L'article étudie la pression exercée sur les parois flexibles d'un silo rectangulaire, tors du remplissage, par le matériau stocké. Les essais realisés sur une maquette grande échelle d'un silo muni d'une trémie pyramidale montrent que l'état de contrainte dans le matériau stocké est fortement dépendante de la flexibilité des parois et des conditions aux limites. Les pressions mesurées sur les parois sont trés différentes de celles prévues par les théories habituelles et par les régles de construction actuelles. Ceci est principalement dû à ce que les théories usuelles s'intéressent uniquement à des silos circulaires à parois rigides et qu'elles ne tiennent pas compte des interactions entre le matériau stocké et la structure. Les origines de la redistribution de pression observée sont étudiées et expliquées.