Open figure viewer
A new method is presented for controlling soil suctions in triaxial tests. The method is based on measurement of suction using thermocouple psychrometers and controlling suctions using the vapour equilibrium technique. The method allows for specimens to be dried/wetted while subjected to externally applied cell pressure and deviator loading. Development of the system and its components is discussed in the text and presented in a series of figures. Operation of the equipment, preparation of the samples, and installation of the specimens are covered. Preliminary test results demonstrate the capability of the system. The results demonstrate that the new suction control...