Rapid load testing methods for piled foundations are generally easier and quicker to mobilise than classic static tests, and are less complex to analyse than dynamic load tests. A recently developed rapid load pile testing method known as the Statnamic test is seeing greater use in the UK for the assessment of piles. For foundation design, it is necessary to derive the equivalent static load-settlement curve from the rapid load test data by eliminating inertial and damping effects. Existing methods of test analysis generally provide good correlation with static tests for sands and gravels, but overpredict pile capacities by up to 50% for clays. In order to gain an insight into the behaviour of rapid load pile testing in clays, a full-scale pile instrumented with accelerometers, strain-gauged sister bars and a tip load cell was tested in a glacial lodgement till near Grimsby, UK. The soil around the pile was also instrumented with radially arrayed buried accelerometers. The test pile was subjected to rapid loading tests, the results of which were compared with constant rate of penetration and maintained load static tests on the same pile. Results from the field testing have been analysed using non-linear viscous parameters obtained from laboratory model and element tests to represent rate-dependent clay shear resistance in the post-yield phase of loading. Shaft frictions derived from the strain-gauged reinforcement in the pile have been compared with shear strains and stresses derived from accelerations in the surrounding soil to give an insight into the load transfer mechanisms for a rapidly loaded pile in clay.
Article navigation
November 2006
Research Article|
November 01 2006
Analysis of a rapid load test on an instrumented bored pile in clay
M. J. Brown;
M. J. Brown
*
Division of Civil Engineering, University of Dundee
UK
Search for other works by this author on:
A. F. L. Hyde;
A. F. L. Hyde
†
Department of Civil and Structural Engineering, University of Sheffield
UK
Search for other works by this author on:
W. F. Anderson
W. F. Anderson
*
Division of Civil Engineering, University of Dundee
UK
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
October 26 2004
Accepted:
August 16 2006
Online ISSN: 1751-7656
Print ISSN: 0016-8505
© 2006 Thomas Telford Ltd
2006
Geotechnique (2006) 56 (9): 627–638.
Article history
Received:
October 26 2004
Accepted:
August 16 2006
Citation
Brown MJ, Hyde AFL, Anderson WF (2006), "Analysis of a rapid load test on an instrumented bored pile in clay". Geotechnique, Vol. 56 No. 9 pp. 627–638, doi: https://doi.org/10.1680/geot.2006.56.9.627
Download citation file:
New and popular articles
Suggested Reading
Thermo-mechanical behaviour of energy piles
Geotechnique (June,2012)
Experimental pile subjected to long duration thrusts owing to a moving slope
Geotechnique (October,2008)
The Selborne cutting stability experiment
Geotechnique (February,1998)
Full-scale observations of dynamic and static axial responses of offshore piles driven in chalk and tills
Geotechnique (December,2019)
Shaft capacity of displacement piles in a high OCR clay
Geotechnique (March,1995)
Related Chapters
An instrumented trial of vibro ground treatment supporting strip foundations in a variable fill
Ground and Soil Improvement
Characterisation of model uncertainties for laterally loaded rigid drilled shafts
Risk and Variability in Geotechnical Engineering
Pore water pressure and horizontal stress changes measured during construction of a contiguous bored pile multi-propped retaining wall in Lower Cretaceous clays
Stiff Sedimentary Clays: Genesis and Engineering Behaviour: Géotechnique Symposium in Print 2007
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
