The response of skirted foundations to combined vertical, horizontal and moment loading is important for the design of offshore installations. The vertical skirts beneath the footing interact with the soil and increase the foundation capacity, compared with a surface footing. Previous researchers have assumed that the soil within the skirts remains rigid during undrained loading, but this assumption has not been investigated rigorously. A series of plane-strain finite element analyses has been conducted to investigate directly how the skirt geometry affects the undrained strip foundation capacity under combined horizontal–moment loading and the mechanisms occurring at failure. Conditions of both uniform and non-uniform undrained strength soil have been considered. The results show that deformation of the soil between external skirts can lead to significantly less foundation capacity than that of an equivalent solid embedded foundation. Hence the specific geometry of the foundation must be considered in design. In addition, the failure envelopes for skirted foundations with different embedment ratios differed significantly. This makes general recommendations for failure envelope shapes problematical. Finally, significant increases in foundation bearing capacity may be achieved by adding an intermediate skirt to the foundation, which results in a foundation capacity that is almost equal to that of a solid embedded foundation.
Article navigation
1 March 2009
Research Article|
March 01 2009
The undrained capacity of skirted strip foundations under combined loading Available to Purchase
M. F. Bransby;
M. F. Bransby
*
University of Dundee
Scotland
Search for other works by this author on:
G.-J. Yun
G.-J. Yun
†
Offshore Engineering Division, Technip UK Limited (formerly University of Dundee)
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
May 28 2007
Accepted:
September 24 2008
Revision Received:
November 12 2008
Online ISSN: 1751-7656
Print ISSN: 0016-8505
© 2009 Thomas Telford Ltd
2009
Geotechnique (2009) 59 (2): 115–125.
Article history
Received:
May 28 2007
Accepted:
September 24 2008
Revision Received:
November 12 2008
Citation
Bransby MF, Yun G (2009), "The undrained capacity of skirted strip foundations under combined loading". Geotechnique, Vol. 59 No. 2 pp. 115–125, doi: https://doi.org/10.1680/geot.2007.00098
Download citation file:
Suggested Reading
Limiting cavity depth for spudcan foundations penetrating clay
Geotechnique (November,2005)
Numerical simulation of pushover tests on a model jack-up platform on clay
Geotechnique (November,2011)
Effect of interface condition on the undrained capacity of subsea mudmats under six-degree-of-freedom loading
Geotechnique (October,2016)
Small-strain, non-linear elastic Winkler models for uniaxial loading of suction caisson foundations
Geotechnique Letters (September,2023)
A simplified mechanically based model for predicting partially drained behaviour of penetrometers and shallow foundations
Geotechnique Letters (September,2011)
Related Chapters
Foundation engineering
The Essence of Geotechnical Engineering: 60 years of Géotechnique
Probabilistic limiting tolerable displacements for serviceability limit state design of foundations
Risk and Variability in Geotechnical Engineering
Partial factors calibration based on reliability analyses for square footings on granular soils
Risk and Variability in Geotechnical Engineering
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
