A novel direct-push (DP) probe was developed for in situ hydraulic conductivity measurements in unconfined sandy aquifers. It is a small-diameter tool with an intake screen and a built-in pressure transducer, and is directly pushed into the ground. Hydraulic conductivity k is estimated by pumping from an aquifer through the intake screen and, while doing so, measuring flow rate and water pressure. This paper describes first the DP system and then the procedures for estimating k values. The finite-element method was employed to obtain intake factors that correlate the measurements with the k values, and these intake factors were compared with those proposed for conventional borehole packer tests. Laboratory and field experiments were also performed to assess the usability of the DP equipment. The results showed that the k estimates obtained from the new probe agreed with those obtained by other methods. The results of this assessment indicate that the proposed DP technique is a promising tool for simple and rapid in situ measurements of hydraulic conductivity. Limitations to the technology are discussed, and further work is suggested.
Article navigation
March 2012
Research Article|
March 01 2012
A constant-head pumping test method using direct-push equipment for in situ hydraulic conductivity measurements
T. KOBAYASHI;
T. KOBAYASHI
*
* Department of Architecture and Civil Engineering, University of Fukui, Japan.
Search for other works by this author on:
H. ONOUE;
H. ONOUE
†
† West Nippon Expressway Co. Ltd, Japan (former student of Kyushu University).
Search for other works by this author on:
S. OBA;
S. OBA
‡
‡ Ministry of Land, Infrastructure, Transport and Tourism, Japan (former student of Kyushu University).
Search for other works by this author on:
N. YASUFUKU;
N. YASUFUKU
§
§ Department of Civil and Structural Engineering, Kyushu University, Japan.
Search for other works by this author on:
* Department of Architecture and Civil Engineering, University of Fukui, Japan.
† West Nippon Expressway Co. Ltd, Japan (former student of Kyushu University).
‡ Ministry of Land, Infrastructure, Transport and Tourism, Japan (former student of Kyushu University).
§ Department of Civil and Structural Engineering, Kyushu University, Japan.
Publisher: Emerald Publishing
Received:
December 15 2009
Accepted:
June 15 2011
Online ISSN: 1751-7656
Print ISSN: 0016-8505
© 2012 Thomas Telford Ltd
2012
Geotechnique (2012) 62 (3): 253–262.
Article history
Received:
December 15 2009
Accepted:
June 15 2011
Citation
KOBAYASHI T, ONOUE H, OBA S, YASUFUKU N, OMINE K (2012), "A constant-head pumping test method using direct-push equipment for in situ hydraulic conductivity measurements". Geotechnique, Vol. 62 No. 3 pp. 253–262, doi: https://doi.org/10.1680/geot.9.P.150
Download citation file:
New and popular articles
Suggested Reading
Diaphragm wall deformation and ground settlement caused by dewatering before excavation in strata with leaky aquifers
Geotechnique (May,2022)
Field determination of mechanical aperture, entry pressure and relative permeability of fractures using NAPL injection
Geotechnique (February,2006)
In situ measurement by chemoprobe of groundwater from in situ sanitation of versatic acid spill
Geotechnique (March,1992)
Limits in determining permeability from on-the-fly uCPT sounding
Geotechnique (October,2007)
An improvement on Hvorslev's shape factors
Geotechnique (December,2006)
Related Chapters
Predict Environmental Conditions Using Groundwater Interpretation in Subdistrict Hamparan Perak, Deli Serdang, North Sumatera
Proceedings of MICoMS 2017
Groundwater control
ICE Manual of Geotechnical Engineering, Volume II: Geotechnical design, construction and verification
Groundwater
The Essence of Geotechnical Engineering: 60 years of Géotechnique
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.