Horizontal strains were measured with high precision during Crossrail tunnel excavation in central London by means of distributed fibre-optic sensors embedded in shallow transverse and longitudinal surface trenches. Validation of these measurements against manual micrometer stick readings demonstrates the benefits of the fibre-optic sensing: high precision at small strains; significantly smaller spatial resolution; and the possibility for automatised measurements over larger spans. In order to further capitalise on these advantages, two additional potential applications of the fibre-optic measurements were investigated: (a) independent assessment of the vertical ground displacements using transverse strain measurements and analytical settlement trough models; and (b) early prediction of the vertical and horizontal ground displacements, using transverse and longitudinal strain measurements and analytical settlement trough models. While understanding that a single case study can only form a basis for limited conclusions, both applications do appear to be feasible.
Article navigation
28 October 2014
Research Article|
October 15 2014
Use of fibre-optic sensors for simple assessment of ground surface displacements during tunnelling
D. HAUSWIRTH;
D. HAUSWIRTH
*
* Institute for Geotechnical Engineering, ETH Zurich, Zurich, Switzerland.
Search for other works by this author on:
A.M. PUZRIN;
A.M. PUZRIN
*
* Institute for Geotechnical Engineering, ETH Zurich, Zurich, Switzerland.
Search for other works by this author on:
A. CARRERA;
A. CARRERA
*
* Institute for Geotechnical Engineering, ETH Zurich, Zurich, Switzerland.
Search for other works by this author on:
J.R. STANDING;
J.R. STANDING
†
† Department of Civil and Environmental Engineering, Imperial College, London, UK.
Search for other works by this author on:
M.S.P. WAN
M.S.P. WAN
‡
‡ Crossrail Ltd, London, UK; Department of Civil and Environmental Engineering, Imperial College, London, UK.
Search for other works by this author on:
* Institute for Geotechnical Engineering, ETH Zurich, Zurich, Switzerland.
† Department of Civil and Environmental Engineering, Imperial College, London, UK.
‡ Crossrail Ltd, London, UK; Department of Civil and Environmental Engineering, Imperial College, London, UK.
Publisher: Emerald Publishing
Received:
March 13 2014
Accepted:
July 08 2014
Online ISSN: 1751-7656
Print ISSN: 0016-8505
© 2014 Thomas Telford Ltd
2014
Geotechnique (2014) 64 (10): 837–842.
Article history
Received:
March 13 2014
Accepted:
July 08 2014
Citation
HAUSWIRTH D, PUZRIN A, CARRERA A, STANDING J, WAN M (2014), "Use of fibre-optic sensors for simple assessment of ground surface displacements during tunnelling". Geotechnique, Vol. 64 No. 10 pp. 837–842, doi: https://doi.org/10.1680/geot.14.T.009
Download citation file:
New and popular articles
Suggested Reading
Behaviour of an old masonry tunnel due to tunnelling-induced ground settlement
Geotechnique (June,2010)
Behaviour of a propped embedded retaining wall at Bell Common Tunnel in the longer term
Geotechnique (December,1989)
The performance of pressure cells for sprayed concrete tunnel linings
Geotechnique (March,2002)
Field measurements on embedded retaining walls
Geotechnique (March,1992)
Using digital image processing in field measurement
Geotechnique (September,1996)
Related Chapters
Soil improvement by the vacuum preloading method for an oil storage station
Ground and Soil Improvement
Installation effects of a bored pile wall in overconsolidated clay
Stiff Sedimentary Clays: Genesis and Engineering Behaviour: Géotechnique Symposium in Print 2007
Widening the Huey P. Long Bridge
Bridge Management 5: Inspection, maintenance, assessment and repair: Proceedings of the 5th International Conference on Bridge Management, organized by the University of Surrey, 11–13 April 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.