Construction of the tunnel for the high-speed Madrid–Barcelona–France railway link across central Barcelona became a major technical and social challenge due to the impact of the tunnel on nearby historic buildings (two of them, the Sagrada Familia basilica and Casa Milà, being United Nations Educational, Scientific and Cultural Organization (Unesco) World Heritage structures). Protection of sensitive buildings from tunnelling-induced movements relied on the construction of a stiff pile wall, separating the tunnel from historic sites. This paper first presents a simplified procedure to analyse the wall–tunnel interaction in a straightforward manner. The main features of the tunnel, excavated by means of an earth pressure balance machine in tertiary clays and sands below the water table, are then described. Details of the design of the wall that was finally built are presented. Issues that were particularly important include the groundwater flow constraints and the use of small-strain soil stiffness properties to obtain realistic settlements. General criteria to design the protection wall are also presented. The good performance of the wall resulted in negligible tunnelling impact on the sensitive structures. The measured and predicted displacements are compared, suggesting that this type of solution is adequate to protect historic structures from tunnelling.
Article navigation
October 2017
Research Article|
August 07 2017
Protecting sensitive constructions from tunnelling: the case of World Heritage buildings in Barcelona
A. Ledesma;
A. Ledesma
*Universitat Politècnica de Catalunya, Barcelona, Spain.
Search for other works by this author on:
E. E. Alonso
E. E. Alonso
*Universitat Politècnica de Catalunya, Barcelona, Spain.
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
March 05 2017
Accepted:
June 27 2017
Online ISSN: 1751-7656
Print ISSN: 0016-8505
© 2017 Thomas Telford Ltd
2017
Geotechnique (2017) 67 (10): 914–925.
Article history
Received:
March 05 2017
Accepted:
June 27 2017
Citation
Ledesma A, Alonso EE (2017), "Protecting sensitive constructions from tunnelling: the case of World Heritage buildings in Barcelona". Geotechnique, Vol. 67 No. 10 pp. 914–925, doi: https://doi.org/10.1680/jgeot.SiP17.P.155
Download citation file:
Suggested Reading
The influence of previous stress history and stress path direction on the surface settlement trough induced by tunnelling
Geotechnique (April,2008)
System to measure three-dimensional movements in physical models
Geotechnique Letters (September,2016)
Analysis of double-O-tube shield tunnelling-induced soil deformation due to ground loss
Geotechnique Letters (February,2016)
Building response and ground movements induced by a deep excavation
Geotechnique (June,2000)
Boundary effects on ground surface rupture induced by normal faulting
Geotechnique Letters (August,2015)
Related Chapters
Tunnelling
The Essence of Geotechnical Engineering: 60 years of Géotechnique
Twin-tunnelling-induced changes to clay stiffness
Tunnelling in the Urban Environment: Géotechnique Symposium in Print 2017
Protecting sensitive constructions from the impact of tunnelling: the case of World Heritage buildings in Barcelona
Tunnelling in the Urban Environment: Géotechnique Symposium in Print 2017
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
