The interaction mechanisms between surface structures and tunnelling-induced ground movements were investigated through centrifuge testing. Although numerous studies have considered this soil–structure interaction problem, previous experiments have neglected important building characteristics and field data inherently contain numerous uncertainties related to the soil, the structure and the tunnelling procedure. Consequently, the interpretation of results and validation of computational models can be problematic. In this study, tunnelling beneath three-dimensional printed structural models with varying building characteristics (i.e. position, length and facade openings) was simulated in a centrifuge. The experimental results demonstrate that tunnelling induces soil displacements at the surface and subsurface that are notably altered due to nearby structures. Specifically, different amounts of vertical and horizontal ground movements, soil dilation and widening of settlement troughs were observed. Building distortions and horizontal building strains were also affected by the relative position of the building to the tunnel, the building length and the area of facade openings. The experimental results provide important data for the evaluation of current design methods and verification of computational models.

Predicting building response to tunnelling-induced settlement is essential for urban tunnelling projects, but remains a challenge due to the complex soil–structure interaction. In particular, finite-element analysis results have shown the critical role played by the building stiffness (Potts & Addenbrooke, 1997; Franzius et al., 2006; Goh & Mair, 2012) and the building weight (Franzius et al., 2004; Giardina et al., 2015a). Parametric studies have enabled the translation of such modelling results into empirical design methods (Potts & Addenbrooke, 1997; Franzius et al., 2006; Goh & Mair, 2012; Giardina et al., 2015a).

These so-called relative stiffness approaches, which relate the building stiffness to the soil stiffness, compare the actual settlements with the settlements in greenfield conditions, where no buildings are present. For most cases, the greenfield settlement profiles transverse to the tunnel are described by a Gaussian curve (Peck, 1969; Schmidt, 1969). Typically, these settlement profiles are predicted by making assumptions on the tunnelling-induced ground loss and the width of the settlement trough, which both depend on the tunnelling method and the ground conditions. The potential soil–structure interaction during the tunnelling procedure is then considered using modification factors, which quantify the alteration of greenfield displacements as a function of the given relative building stiffness. Fig. 1 conceptually depicts the modification of the vertical soil displacements above a tunnel due to a nearby structure and defines the deflection ratios (DRs) of the building settlement profile and the greenfield equivalent. For structures spanning the point of inflection, i, of the vertical settlement profile, it is commonly assumed to separate a building into its hogging and sagging region (Mair et al., 1996). Potts & Addenbrooke (1997) quantified the soil–structure interaction in terms of modification factors (M) for the deflection ratio as

1a
1b
Fig. 1.

(a) Influence of soil–structure interaction on building distortions. (b) Definition of the relative deflection ratios (DRs) for the structure (Str) and the greenfield (GF) in sagging and hogging

Fig. 1.

(a) Influence of soil–structure interaction on building distortions. (b) Definition of the relative deflection ratios (DRs) for the structure (Str) and the greenfield (GF) in sagging and hogging

Close modal

Modification factors for the horizontal strain were also defined to estimate a potential change of the horizontal greenfield ground strains due to a nearby structure (Potts & Addenbrooke, 1997) as

2a
2b

where εhc and εht are the compressive and tensile horizontal strains of the structure (Str) or the greenfield equivalent (GF).

Although these relative building stiffness methods highlight the soil–structure interaction effects, surface structures are simplified as elastic beams and building characteristics (e.g. facade openings or non-linear material behaviour) are not considered. Consequently, uncertainty still exists about the impact of building features on this interaction problem. Furthermore, the extent to which horizontal ground strains are transferred to buildings is still debated. As a consequence, predictions based on these relative stiffness methods might differ and, in certain scenarios, can lead to underestimation of building risk to tunnel excavation (Camós et al., 2014).

The primary data for validating current design approaches are provided by case studies of building performance to tunnel excavation. However, field data are frequently affected by various sources of uncertainty, including the tunnelling procedure, the ground conditions and the nature of the existing buildings, and thus interpretation can be problematic. Moreover, reported soil–structure interaction data are frequently based on monitoring points located on the building facade (e.g. Frischmann et al., 1994; Lu et al., 2001; Viggiani & Standing, 2001; Bilotta et al., 2017) and information about the soil behaviour below the structure is scarce. Experimental laboratory studies can provide a controlled environment to study the interaction between existing surfaces structure and tunnel excavation. Specifically, centrifuge models, which replicate prototype stress conditions in the soil and the building model, have provided useful data (Taylor & Grant, 1998; Caporaletti et al., 2006; Farrell & Mair, 2010). However, these studies were limited by relatively few building positions and rather simple building models, which can result in uncertainty when assessing building performance. For example, numerous researchers have noted that ignoring facade openings can substantially overestimate the building bending stiffness (e.g. Melis & Rodriguez Ortiz, 2001; Son & Cording, 2007; Dimmock & Mair, 2008; Goh & Mair, 2011).

The main aim of the work reported in this paper was to gain better understanding of the influence of building position and features on the tunnel–soil–building interaction problem. Therefore, the effects of building location, length and facade openings on the soil and building response were experimentally investigated. Results from a series of centrifuge model tests involving realistic three-dimensional (3D) printed building models exposed to a shallow tunnel excavation in dry, dense sand are presented. After introducing the centrifuge modelling set-up, the differences between greenfield soil displacements and ground movements modified by the building models are summarised. The effect of varying building features on structural performance is then measured by means of building deformation parameters (i.e. deflection ratio and horizontal strain), and soil–structure interaction effects are quantified in terms of modification factors.

Centrifuge experiments at an acceleration level, N, of 75 times the Earth's gravity field, g, were performed. Fig. 2 provides the basic dimensions of the centrifuge model, which replicates a 75 times larger tunnelling project with a cover-to-tunnel diameter ratio, C/D, of 1·35. While the soil conditions were kept constant, the building eccentricity, e, the building length, L, and the area of facade openings, O, varied between tests, as summarised in Fig. 3. The results of a greenfield test performed by Farrell (2010), which replicated the identical tunnelling prototype, are also presented in this paper.

Fig. 2.

Framework to assess building response to tunnelling (dimensions in mm). LVDT, linear variable differential transformer; PMMA, poly(methyl methacrylate)

Fig. 2.

Framework to assess building response to tunnelling (dimensions in mm). LVDT, linear variable differential transformer; PMMA, poly(methyl methacrylate)

Close modal
Fig. 3.

Centrifuge test series with varying building length L, building position e and facade openings O: test A, e/L = 0, L/H = 2·2, O = 20%; test B, e/L = 0·8, L/H = 2·2, O = 20%; test C, e/L = 0·5, L/H = 2·2, O = 20%; test D, e/L = 0·8, L/H = 2·2, O = 40%; test E, e/L = 0·5, L/H = 2·9, O = 20%; test F, e/L = 0·5, L/H = 2·9, O = 40%

Fig. 3.

Centrifuge test series with varying building length L, building position e and facade openings O: test A, e/L = 0, L/H = 2·2, O = 20%; test B, e/L = 0·8, L/H = 2·2, O = 20%; test C, e/L = 0·5, L/H = 2·2, O = 20%; test D, e/L = 0·8, L/H = 2·2, O = 40%; test E, e/L = 0·5, L/H = 2·9, O = 20%; test F, e/L = 0·5, L/H = 2·9, O = 40%

Close modal

A dry silica sand (Leighton Buzzard fraction E) with the properties presented in Table 1 was used throughout the test series. The sand was poured to an average relative density, ID, of 90% (±3%) using a sand pouring robot (Madabhushi et al., 2006).

Table 1.

Physical properties of Leighton Buzzard fraction E silica sand (Haigh & Madabhushi, 2002)

PropertyValue
D10 grain size: mm0·095
D50 grain size: mm0·14
D60 grain size: mm0·15
Minimum voids ratio, emin0·613
Maximum voids ratio, emax1·014
Specific gravity, Gs2·67
Critical state friction angle, ϕcrit: degrees32

The model tunnel consisted of a rigid brass cylinder and a flexible latex membrane that was sealed to the end caps of the brass cylinder using wire. The cavity between the latex membrane and the brass cylinder was filled with water, and tunnelling-induced volume loss was simulated by extracting the water. This technique allows various volume losses to be simulated within a single experiment. Numerous researches have used this fluid-extraction approach (e.g. Loganathan et al., 2000; Farrell & Mair, 2012; Marshall et al., 2012; Franza & Marshall, 2016). During acceleration of the centrifuge, the tunnel pressure was balanced with the vertical soil stresses at the tunnel axis to minimise ground movements surrounding the tunnel (Ritter et al., 2017).

A total of six building models were 3D printed on a ZCorporation Zprinter350 using Visijet PXL Core powder and Visijet PXL clear binder. Due to the 3D printing technique, building details (facade openings, strip footings, a rough foundation base and intermediate walls) were reproduced at a scale of 1:75, as shown in Fig. 4. In every print job, model beam specimens were printed and subsequently tested in four-point bending. Table 2 summarises the derived 3D printed material properties of the building models. A comparison with typical properties of masonry (Giardina et al., 2015b) indicated that the 3D printed material had a lower density than masonry, a Young's modulus comparable to that of historic masonry and higher flexural strength and ultimate strain. Accordingly, the building cross-sections were adjusted to obtain global bending stiffness, EI, and axial stiffness, EA, values frequently reported in case studies (e.g. Mair & Taylor, 2001; Dimmock & Mair, 2008; Farrell et al., 2012). Table 3 summarises the building configurations, the building stiffness values in model and prototype scale (which were obtained following Farrell et al. (2012)) and the important dimensionless groups of this soil–structure interaction problem. A reduction of the global building bending stiffness due to facade openings was considered by applying the reduction factors proposed by Melis & Rodriguez Ortiz (2001) to the EI values for the walls while the EA values ignore facade openings. As can be seen in Fig. 4(a), dead load bars were placed on top of the building models to obtain a constant bearing pressure of 100 kPa beneath the footings transverse to the tunnel.

Fig. 4.

3D printed building model (dimensions in mm). DIC, digital image correlation

Fig. 4.

3D printed building model (dimensions in mm). DIC, digital image correlation

Close modal
Table 2.

Material properties of the used 3D printed material; the masonry properties are according to Giardina et al. (2015b) 

Density, ρ: kg/m3Flexural strength,ft: MPaYoung's modulus,E: MPaUltimate strain to failure, εult: %
Test A12931·362893·10·298
Test B12781·311800·60·357
Test C12611·130727·40·282
Test D12720·934516·00·352
Test E12801·139689·90·309
Test F12471·7021039·20·246
Mean12721·263777·70·307
Masonry*19000·1–0·91000–90000·05
*

According to Giardina et al. (2015a, 2015b).

Strain at onset of cracking for brick walls (Burland & Wroth, 1974).

Table 3.

Details of the test series

TestModel scalePrototype scale*Dimensionless
groups
e: mmL: mmH: mmO: %EAm:
kN/m
EIm:
kNm2/m
EAp:
kN/m
EIp:
kNm2/m
e/LL/H
A020090207·5 × 1034·05·3 × 1051·5 × 10602·2
B16020090206·7 × 1033·64·8 × 1051·3 × 1060·82·2
C10020090206·1 × 1033·34·3 × 1051·2 × 1060·52·2
D16020090404·3 × 1031·13·1 × 1054·0 × 1050·82·2
E13026090205·8 × 1033·14·1 × 1051·1 × 1060·52·9
F13026090408·7 × 1032·26·2 × 1058·1 × 1050·52·9
*

The used scale factor (i.e. N = 71·6) was obtained at mid-height of building models.

The structural model was placed on top of the sand model before centrifuge acceleration. Subsequently, the tunnel excavation was performed. Throughout the experiments, images were captured with three digital cameras positioned in front of the poly(methyl methacrylate) (PMMA) window. These images were used to derive displacements of the ground and building model by applying digital image correlation (DIC) using the software GeoPIV (White et al., 2003). Further instrumentation in the form of linear variable differential transformers (LVDTs) and laser displacements sensors enabled evaluation of the image-based measurements and quantification of the boundary effects between the PMMA window and the soil. Further details about the experimental set-up and modelling effects are reported elsewhere (Ritter et al., 2017).

The presence of surface structures alters settlement profiles associated with the tunnelling procedure. However, there is a lack of data quantifying the tunnelling-induced soil movements beneath adjacent buildings. Thus, alteration of the soil response is first explored.

Vertical soil surface displacements

Surface settlement profiles at a tunnel volume loss (Vl,t) of 2·0% are given in Fig. 5. The entire set of tests modified the settlement troughs. The structure in test A, which was placed symmetric to the tunnel, substantially reduced the vertical ground movements above the tunnel compared with the greenfield equivalent. A slight reduction in vertical ground settlements above the tunnel was also observed in test B. In contrast, the structure with a building end located above the tunnel (test C) caused substantially greater vertical soil displacements in the same area. This localised effect for a tunnel excavated underneath a building end was also observed by Liu et al. (2001) and Bilotta et al. (2017). Contrary to structure A, structures B and C increased the vertical soil displacements beneath the centre of the building, which was away from the tunnel centre-line.

Fig. 5.

Building effects on vertical surface soil displacements at a tunnel volume loss of 2·0%: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings

Fig. 5.

Building effects on vertical surface soil displacements at a tunnel volume loss of 2·0%: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings

Close modal

Figure 5(b) shows that an increase in the amount of openings from 20% to 40% of the area of the building facade slightly reduced the modification of the greenfield soil movements underneath the centre of structures D and F. This is likely caused by the greater opening percentage, which increased flexibility. Structure F also caused substantially greater soil settlements beneath the left-hand building edge, demonstrating that higher flexibility in the hogging region caused increased embedment above the tunnel. By contrast, for structure E, which had 20% openings but was otherwise similar to test F, the reduced curvature of the vertical soil settlement profile beneath the building indicates a less flexible response, which then decreased embedment above the tunnel (Fig. 5(b)). These findings confirm that the amount of window area changes a building's flexibility, which then affects soil displacement. Fig. 5(b) also indicates that the building length directly affected the modification of the vertical surface soil displacements.

Ground loss

Empirical methods to estimate ground movements caused by the tunnelling process are generally based on assumptions about the induced ground loss. In granular soils, shearing causes volume changes of the soil above the tunnel and, for greenfield conditions, the volumes of the settlement troughs vary with depth (Hansmire & Cording, 1985; Marshall et al., 2012). For shallow tunnels in dense sand, Marshall et al. (2012) reported substantial dilation of the soil body above the tunnel, which reduced the volume of the soil settlement trough, Vl,s, compared with the tunnel volume loss, Vl,t.

Figure 6 was obtained by numerical integration of the vertical soil displacement profiles and indicates the building effects on Vl,s. At the soil surface (Figs 6(a) and 6(b)) and at half the tunnel depth (z/zt = 0·5) (Fig. 6(c)), an overall dilative behaviour was observed. Particularly, as Vl,t increased, the rate of increase of Vl,s decreased.

Fig. 6.

Soil volume loss, Vl,s, plotted against tunnel volume loss, Vl,t: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings; (c) subsurface soil volume loss at z/zt = 0·5

Fig. 6.

Soil volume loss, Vl,s, plotted against tunnel volume loss, Vl,t: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings; (c) subsurface soil volume loss at z/zt = 0·5

Close modal

Figure 6(a) shows that the building position influenced the ground loss. While the values of Vl,s below buildings placed eccentric to the tunnel (tests B and C) were in good agreement with the greenfield Vl,s, an identical building model positioned at zero eccentricity (test A) resulted in a notably lower value of Vl,s above Vl,t = 1·5% (Fig. 6(a)). For long buildings (tests E and F), the surface ground loss was greater than for the greenfield case (Fig. 6(b)). An increase in openings from 20% to 40% showed a minor influence on Vl,s. In contrast, at the subsurface, all the building models lowered Vl,s similarly when compared with the greenfield values (Fig. 6(c)).

The effect of building weight contributes to ground loss results. As reported by Franzius et al. (2004), a building surcharge increases the mean effective stresses in the soil body, which then leads to greater soil stiffness and strength. Consequently, the ground movements surrounding a tunnel reduce, as is evident in Fig. 7. This lower magnitude of soil displacements above the tunnel crown explains the lower value of Vl,s at half the tunnel depth (z/zt = 0·5) shown in Fig. 6(c). The pivotal role of the building weight in this soil–structure interaction problem was also pointed out by Giardina et al. (2015a) and Bilotta et al. (2017).

Fig. 7.

Vertical soil displacements at a tunnel volume loss of 2·0%: (a) greenfield test (Farrell, 2010) and test A (building symmetric to tunnel); (b) test F (building asymmetric to tunnel)

Fig. 7.

Vertical soil displacements at a tunnel volume loss of 2·0%: (a) greenfield test (Farrell, 2010) and test A (building symmetric to tunnel); (b) test F (building asymmetric to tunnel)

Close modal

The volumetric soil behaviour above the tunnel was further clarified by the observed engineering shear strains and volumetric strains (Figs 8 and 9). Fig. 8(a) shows that building load reduced the amount of shear strains compared with the greenfield scenario, and the soil beneath the building of test A showed less dilation (negative εvol in Fig. 9(a)).

Fig. 8.

Engineering shear strains at a tunnel volume loss of 2·0%: (a) greenfield test and test A (building symmetric to tunnel); (b) test F (building asymmetric to tunnel)

Fig. 8.

Engineering shear strains at a tunnel volume loss of 2·0%: (a) greenfield test and test A (building symmetric to tunnel); (b) test F (building asymmetric to tunnel)

Close modal
Fig. 9.

Volumetric strains at a tunnel volume loss of 4·0% (εvol < 0 indicates dilation): (a) greenfield test and test A (building symmetric to tunnel); (b) test F (building asymmetric to tunnel)

Fig. 9.

Volumetric strains at a tunnel volume loss of 4·0% (εvol < 0 indicates dilation): (a) greenfield test and test A (building symmetric to tunnel); (b) test F (building asymmetric to tunnel)

Close modal

The influence of surface structures on soil shear strains was confirmed by the asymmetric shear strain contours monitored for buildings placed asymmetric to the tunnel (Fig. 8(b)). The building seems to have a negligible effect on the shear strains above the left-hand tunnel shoulder, showing shear strains similar to the greenfield case shown in Fig. 8(a). However, the structure reduced the shear strains above the right-hand tunnel shoulder, as shown in Fig. 8(b). A considerable amount of volumetric contraction was measured beneath the building (Fig. 9(b)), which confirms the increase in Vl,s at z/zt = 0 for tests E and F.

Although the building load, position and length clearly influenced the volumetric behaviour of the soil, and thus the tunnelling-induced ground loss, all tests showed rather similar values of Vl,s for practical volume loss (i.e. Vl,s < 1·5%).

Settlement trough width

The settlement trough width is widely used as an input parameter when empirically predicting tunnelling-induced ground movements. Therefore, the influence of building features on the width of vertical settlement profiles was explored.

Modified Gaussian curves were fitted to the vertical soil displacements because their additional degree of freedom provides a better fit to settlement profiles in drained soil than Gaussian curves (Vorster, 2002; Marshall et al., 2012). For structures located at an offset from the tunnel (i.e. tests B to F), asymmetric settlement troughs were obtained (Fig. 5) and thus the curve fitting was carried out for the right-hand side only.

To quantify the trough width of the modified Gaussian curves, the framework proposed by Marshall et al. (2012) was adopted. Therefore, the trough width parameter, K*, for modified Gaussian curves was calculated, which is similar to estimating the more traditional trough width, K, for Gaussian curves. To estimate K*, the parameter x*, which is the offset from the tunnel centre-line where vertical surface soil displacement Sv = 0·606Sv,max, was first determined. This parameter (x*) is similar to the inflection point, i, of a Gaussian curve because Sv(i) = 0·606Sv,max. K* was subsequently obtained for different soil depths by dividing x* by the depth to the tunnel axis (i.e. zt − z).

Figure 10(a) shows the effect of different building positions on the surface trough width parameter, K*s. For all the tests, the buildings widened the transverse surface soil settlement troughs beneath them. Buildings placed closer to the tunnel (test A) caused the greatest K*s values, while the trough width became narrower as e/L increased.

Fig. 10.

Surface trough width parameter, K*s, plotted against tunnel volume loss, Vl,t: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings. † Mair & Taylor (1997) 

Fig. 10.

Surface trough width parameter, K*s, plotted against tunnel volume loss, Vl,t: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings. † Mair & Taylor (1997) 

Close modal

Figure 10(b) shows the relationships between building length, area of facade openings and K*s. For the shorter buildings (L/H = 2·2), an increase in openings from 20% to 40% had little effect on K*s. However, for the longer buildings (L/H = 2·9), doubling the window area significantly narrowed the settlement trough. In this case, the increased flexibility caused the settlement profile to deviate less from the greenfield equivalent. A similar effect was not observed for the shorter structure (L/H = 2·2) because test D performed rather rigidly despite having an openings area of 40%. Clearly, and as expected, the building position, length and area of openings need to be considered in combination. The observed widening of the settlement profiles due to an adjacent structure is consistent with field data (e.g. Frischmann et al., 1994; Lu et al., 2001; Viggiani & Standing, 2001), although these investigations were based on facade monitoring points.

Although x* and K* provide a valuable approach to investigate the settlement trough width, these parameters are less suitable to estimate hogging and sagging modes of displacement profiles, which are defined by the inflection point of the associated settlement trough. The partitioning between hogging and sagging is particularly important for building damage assessment, for which Mair et al. (1996) proposed to separate buildings at the inflection point. Therefore, Fig. 11 provides the variation of the inflection point, imG,s, of the modified Gaussian curves fitted to the surface soil settlements. As expected, the data in Fig. 11 indicate similar trough width trends as Fig. 10, but the figure emphasises the fact that the soil–structure interaction has a significant impact on the greenfield inflection point. This outcome implies that treating a building separately either side of the assumed greenfield inflection point might result in substantial uncertainty when predicting building performance to tunnelling subsidence.

Fig. 11.

Inflection points of the modified Gaussian curves fitted to surface soil settlements: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings

Fig. 11.

Inflection points of the modified Gaussian curves fitted to surface soil settlements: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings

Close modal

The focus of the paper thus far has been the vertical soil response, but the effect of buildings on horizontal ground movements is also important for the assessment of both surface and subsurface structures.

Horizontal soil surface displacements

Figure 12 presents the horizontal surface ground movements that complement the vertical ground movement profiles given in Fig. 5. In all the tests, the building models substantially restricted the horizontal ground movements beneath them. Fig. 12(a) indicates that the building-to-tunnel position had only a minor influence on the restraining effect of the buildings on the horizontal soil movements. Likewise, Fig. 12(b) shows that this restraint was also observed for buildings with different lengths and facade openings. It follows that the analysed building variations had a relatively small effect on the axial building stiffness and shear failure was not observed at the soil–structure interface.

Fig. 12.

Effect of soil–structure interaction on horizontal surface soil displacements at tunnel volume loss of 2·0%: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings

Fig. 12.

Effect of soil–structure interaction on horizontal surface soil displacements at tunnel volume loss of 2·0%: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings

Close modal

The horizontal ground movements beyond the edge of the surface structures were also affected by the presence of the buildings. In Fig. 12(b) this is particularly evident to the left of the structures B and D, until the greenfield displacements were again restored at a horizontal distance of approximately 30 mm from the left-hand building edge. Similar findings for building effects on horizontal ground movements were reported by Potts & Addenbrooke (1997).

Horizontal soil subsurface displacements

Figure 13 shows the horizontal soil displacement with depth at an offset from the tunnel centre-line of x = 70 mm. For all the soil–structure interaction tests, buildings were present at that x position. Close to the soil surface, the restraining effect of the soil–structure interaction is clearly visible in Fig. 13. However, at a soil depth between z/zt values of 0·13 and 0·26, the horizontal ground movements were in fair agreement with the greenfield displacements (Standing, 2001; Farrell, 2010). These findings are the results of the rough soil–structure interface and indicate that the restraining effect of the building on the horizontal soil movements is a rather shallow mechanism; slippage between the foundation and the soil surface was not observed. At z/zt > 0·26, the slightly lower horizontal ground displacements measured in the soil–structure tests compared with the greenfield case can be attributed to the greater soil stiffness, as mentioned earlier. The variation of horizontal soil displacements with depth was unaffected by the differing building features.

Fig. 13.

Horizontal soil displacement, Sh, profiles at x = 70 mm and a tunnel volume loss, Vl,t, of 2·0%: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings

Fig. 13.

Horizontal soil displacement, Sh, profiles at x = 70 mm and a tunnel volume loss, Vl,t, of 2·0%: (a) effect of building eccentricity (constant L and O); (b) effect of building length and facade openings

Close modal

Having discussed the impact of buildings on tunnelling-induced settlements, this section describes the building performance using widely accepted building deformation parameters, namely the deflection ratio and horizontal strain. The soil–structure interaction effects are quantified in terms of modification factors.

Figure 14 shows the variation of the deflection ratios with volume loss in sagging and hogging. The building subdivision into hogging and sagging was carried out using the inflection point associated with the modified Gaussian curves fitted to the vertical surface soil displacement profiles (Fig. 11). To reduce the GeoPIV measurement noise, the vertical displacements at the base of the surface structures were smoothed by fifth-order polynomials. This curve-fitting approach provided a significantly better fit than the modified Gaussian curves, which tended to overestimate the building deflections. Subsequently, for structures spanning the hogging/sagging transition zone, the deflection ratios were estimated individually for both the hogging and sagging mode. The observed scatter in DRsag for tests C, E and F was caused by small sagging regions and small measurements of building distortion.

Fig. 14.

Deflection ratios of the soil–structure interaction tests

Fig. 14.

Deflection ratios of the soil–structure interaction tests

Close modal

The adopted hogging/sagging subdivision implies that the building-to-tunnel position plays a key role, which can also be observed in Fig. 14. The building placed at zero eccentricity (test A) caused a positive deflection ratio (DRsag) while an equal building positioned at e/L = 0·8 (test B) showed a hogging mode of deflection (DRhog) and is thus likely to be at greater risk of building damage (Mair et al., 1996). On the other hand, test C, in which the building was spanning the hogging/sagging region, showed a hogging and sagging response and caused an even greater DRhog than that in test B. This indicates that structures positioned in the hogging/sagging transition zone of the tunnelling-induced settlement trough are potentially more vulnerable to building damage.

As the building length and the facade opening percentage increased, greater deflection ratios were measured (Fig. 14). This is particularly evident for the hogging mode of deflection and can be explained by a more flexible building response. For test D, the increase in window area nearly doubled the DRhog value of test B, in which the building was of identical length and eccentricity. Likewise, DRhog substantially increased for the long structure with an openings area of 40% (test F) compared with the equally long structure with 20% openings (test E).

With respect to the building length, the magnitude of DRhog nearly doubled when the building length increased from L/H = 2·2 to L/H = 2·9. This can be clearly seen when comparing the DRhog trends of test E to tests B and C in Fig. 14. Specifically, the comparison between tests D and F highlights the effect of the building length on DRhog.

In Fig. 15, the data from Fig. 14 are compared with the associated greenfield deflection ratios, which were obtained by using the greenfield soil settlement profiles and taking the corresponding building-to-tunnel position into account. The obtained modification factors for the deflection ratio in sagging, MDRsag, and hogging, MDRhog, were generally below unity. This indicates that the building deflections were lower than the greenfield equivalent.

Fig. 15.

Modification factors for deflection ratios

Fig. 15.

Modification factors for deflection ratios

Close modal

The modification factors vary with building features. While minor differences were obtained for MDRsag, the different building characteristics substantially altered MDRhog. Interestingly, a change in building position from e/L = 0·8 (test B) to e/L = 0·5 (test C) did not affect MDRhog (Fig. 15). Conversely, an increase in the building length and facade openings caused greater values of MDRhog and, for the long structure of test F with 40% of facade openings, hogging deflections similar to the greenfield case were observed (i.e. MDRhog = 1). Notably, these high MDRhog values for test F occurred at tunnel volume losses below 1·0%. The remaining tests showed building distortions lower than about 65% of the greenfield values for the entire range of tunnel volume loss studied.

Horizontal building strains were determined from the slope of a linear curve fitted to the horizontal displacements of the sagging and hogging regions of the building. The horizontal displacements were obtained close to the base of the building and the hogging/sagging partitioning was again based on imG,s. Fig. 16 shows the obtained horizontal strains in compression, εhc, and tension, εht. In particular, it can be seen that εhc was affected by small sagging regions that caused substantial scatter when deriving εhc.

Fig. 16.

Average horizontal strain at base of buildings (tension is negative)

Fig. 16.

Average horizontal strain at base of buildings (tension is negative)

Close modal

The data in Fig. 16 show only compressive strains for structures C and E. It is likely that this result is related to a rigid-body rotation of the building towards the tunnel, which then caused an embedment of the left-hand building corner (Fig. 5). Consequently, the horizontal movement of the structure was substantially constrained above the tunnel and compressive horizontal strains were measured. For test A, which was predominantly placed in the sagging zone, compressive strains were derived while an identical building placed at e/L = 0·8 (test B) showed tensile strains. Slightly greater tensile strains were monitored for the building of test D, which had the same length and location as the structure in test B but 40% of openings. The greatest tensile strains were, however, measured for test F, which is identical to the DRhog results. The increase in building length and facade openings caused substantially greater horizontal building tensile strains. Nevertheless, the obtained horizontal building strains were in ‘category 0’ (negligible) when adopting the damage category chart defined by Burland (1995) and strains caused by the building deflection are neglected.

Figure 17 shows the modification factors for the horizontal strain in compression Mεhc and tension Mεht. In all the tests, the compressive strains were generally below 10% of the corresponding average horizontal greenfield strains, which were obtained following Mair et al. (1996). The greater values at a Vl,t value of about 0·5% are most likely due to noise in the GeoPIV data. In tension, considerably greater modification factors were observed for test F, with average horizontal building tensile strains of about 40% compared with the greenfield case. The results of test F were followed by test D, which indicates that buildings with a larger window area might be more susceptible to horizontal tensile strains.

Fig. 17.

Modification factors for horizontal strains

Fig. 17.

Modification factors for horizontal strains

Close modal

Experimental data of a centrifuge test series on building response to a shallow tunnel excavation in dry, dense sand have been presented. Building characteristics (e.g. a rough soil–structure interface, strip footings, intermediate walls and facade openings) were replicated by 3D prints of building models. The following conclusions can be drawn from the experimental results.

  • Vertical soil surface displacements exceeding the greenfield values were observed when the tunnel excavation passed directly underneath a building corner. Similar results were reported by Liu et al. (2001) and Bilotta et al. (2017). This phenomenon reduced for the stiffer longer building tested.

  • A structure in close proximity to the tunnel excavation changed the volumetric behaviour of the soil above the tunnel and the tunnelling-induced displacement field. Similar building weight effects were also identified previously (Franzius et al., 2004; Giardina et al., 2015a, 2015b; Bilotta et al., 2017). Consequently, the observed surface and subsurface volume losses were affected by nearby structures. Long structures caused volumetric soil contraction beneath them and the surface volume loss values were greater than those of the greenfield case. Structures placed symmetrically to the tunnel reduced the surface volume loss while the area of facade openings showed only a minor influence.

  • The presence of buildings widened the vertical soil settlement trough compared with the greenfield case. The widest trough was obtained for a structure with zero eccentricity and the trough became narrower as the distance between the building and the tunnel increased. An increase in flexibility of the building, caused by a greater building length and/or a greater area of facade openings, reduced this widening effect. Field data of building displacement profiles above tunnels confirm these findings (Frischmann et al., 1994; Lu et al., 2001; Viggiani & Standing, 2001).

  • The absolute and differential horizontal ground displacements just beneath the surface structures were significantly restrained by the buildings. However, the horizontal greenfield soil movements were recovered at a soil depth between z/zt = 0·13 and 0·26, which is in fair agreement with the findings of Standing (2001) and Farrell (2010). Changes in the relative position of the building to the tunnel, the building length and the facade openings had little effect on the reduction of horizontal ground movements.

  • Building stiffness plays a key role in the building's response to tunnel excavation and predictions based on greenfield assumptions are, in general, overly conservative. However, the centrifuge experiments showed that the building-to-tunnel position, the building length and the amount of facade openings are also important factors. In the sagging region, the measured building distortions were below 40% of the greenfield equivalent. The building characteristics had a minor influence on the sagging deflections. However, in hogging, significantly greater building distortions were observed with increases in building length and the percentage of facade openings. For a tunnel passing beneath the building corner of a long flexible structure with 40% openings, building deflections equal to the greenfield case were obtained, even at tunnel volume losses below 1·0%.

  • Structures located in the hogging and sagging regions of the tunnelling-induced settlement profile were more vulnerable (in terms of the deflection ratio) than buildings of identical length positioned entirely in sagging or hogging.

  • For most of the investigated cases, the horizontal strains induced in the structures were negligible, as has been observed in the field (Mair, 2013) and in previous centrifuge experiments (Farrell & Mair, 2012). However, for structures with a considerable area of openings, average horizontal building strains of up to 40% of the greenfield equivalent were measured. This indicates that horizontal strains, although considerably less than those predicted using greenfield conditions, might be appreciable in flexible structures.

The centrifuge modelling carried out enabled these new insights into the mechanism of tunnelling-induced ground displacements on surface structures. A limitation of this work is that the 3D effects of tunnel advancement, which might cause an adverse torsional response of the building, were not studied. The obtained data also provide important new information with which to evaluate the currently available design procedures that are based on relative stiffness expressions. In addition, the results of this study provide useful benchmark data for computational modelling.

The authors thank the Engineering and Physical Sciences Research Council (grant EP/KP018221/1) and Crossrail for financially supporting this research. The technicians of the Schofield Centre are acknowledged for their contribution when running the centrifuge test series. Special thanks go to Dr Ruaidhri P. Farrell for sharing greenfield data. The related research data are available at https://doi.org/10.17863/CAM.10554.

B

building width

C

cover

D

tunnel diameter

DR

deflection ratio

E

Young's modulus

EA

axial stiffness

EI

bending stiffness

e

building eccentricity

emax

maximum voids ratio

emin

minimum voids ratio

ft

flexural strength

Gs

specific gravity

g

Earth's gravity field

H

building height

ID

relative density

i

point of inflection

K

trough width

K*

trough width parameter

Ks

surface trough width parameter

L

building length

M

modification factor

O

facade openings

Sh

horizontal soil displacement

Sv

vertical soil displacement

Vl,s

volume of soil settlement trough

Vl,t

tunnel volume loss

z

depth

zt

tunnel depth

εhc

compressive horizontal strain of the structure

εht

tensile horizontal strain of the structure

εult

ultimate strain to failure

ρ

density

ϕcrit

critical state friction angle

Bilotta
,
E.
,
Paolillo
,
A.
,
Russo
,
G.
&
Aversa
,
S.
(
2017
).
Displacements induced by tunnelling under a historical building
.
Tunn. Undergr. Space Technol.
61
,
221
232
, .
Burland
,
J.
(
1995
). Assessment of risk of damage to buildings due to tunnelling and excavations. In
Proceedings of the 1st international conference on earthquake geotechnical engineering (IS-Tokyo’95)
(ed.
K.
Ishihara
), pp.
1189
1201
.
Tokyo, Japan
:
Balkema
.
Burland
,
J.
&
Wroth
,
C.
(
1974
). Settlement of buildings and associated damage. In
Proceedings of the conference on settlement of structures
, pp.
611
654
.
London, UK
:
Pentech Press
.
Camós
,
C.
,
Molins
,
C.
&
Arnau
,
O.
(
2014
).
Case study of damage on masonry buildings produced by tunneling induced settlements
.
Int. J. Architect. Heritage
8
,
No. 4
,
602
625
.
Caporaletti
,
P.
,
Burghignoli
,
A.
&
Taylor
,
R.
(
2006
). Centrifuge study of tunnel movements and their interaction with structures. In Geotechnical aspects of underground construction in soft ground (eds
K. J.
Bakker
,
A.
Bezuijen
,
W.
Broere
and
E. A.
Kwas
), pp.
99
105
.
Boca Raton, FL, USA
:
CRC Press
.
Dimmock
,
P. S.
&
Mair
,
R. J.
(
2008
).
Effect of building stiffness on tunnelling-induced ground movement
.
Tunn. Undergr. Space Technol.
23
,
No. 4
,
438
450
.
Farrell
,
R.
(
2010
).
Tunnelling in sands and the response of buildings
.
PhD thesis
,
University of Cambridge
,
Cambridge, UK
.
Farrell
,
R.
&
Mair
,
R.
(
2010
). Centrifuge modelling of the response of buildings to tunnelling. In
Physical modelling in geotechnics
(eds
S.
Springman
,
J.
Laue
and
L.
Seward
), vol.
1
, pp.
549
554
.
Boca Raton, FL, USA
:
CRC Press
.
Farrell
,
R.
&
Mair
,
R.
(
2012
). Centrifuge modelling of the response of buildings to tunnelling. In
Geotechnical aspects of underground construction in soft ground
(ed.
G.
Viggiani
), pp.
343
351
.
Boca Raton, FL, USA
:
CRC Press
.
Farrell
,
R.
,
Mair
,
R.
,
Sciotti
,
A.
,
Pigorini
,
A.
&
Ricci
,
M.
(
2012
). The response of buildings to tunnelling: a case study. In
Geotechnical aspects of underground construction in soft ground
(ed.
G.
Viggiani
), pp.
877
885
.
Boca Raton, FL, USA
:
CRC Press
.
Franza
,
A.
&
Marshall
,
A. M.
(
2016
). Centrifuge modelling of piled structure response to tunnelling. In
Eurofuge 2016, 3rd European conference on physical modelling in geotechnics
(eds
L.
Thorel
,
A.
Bretschneider
,
M.
Blanc
and
S.
Escoffier
), pp.
313
318
.
Marne la Vallée, France
:
IFSTTAR
.
Franzius
,
J. N.
,
Potts
,
D. M.
,
Addenbrooke
,
T. I.
&
Burland
,
J. B.
(
2004
).
The influence of building weight on tunnelling-induced ground and building deformation
.
Soils Found.
44
,
No. 1
,
25
38
.
Franzius
,
J. N.
,
Potts
,
D. M.
&
Burland
,
J. B.
(
2006
).
The response of surface structures to tunnel construction
.
Proc. Instn Civ. Engrs – Geotech. Engng
159
,
No. 1
,
3
17
, .
Frischmann
,
W.
,
Hellings
,
J.
,
Gittoes
,
G.
&
Snowden
,
C.
(
1994
).
Protection of the Mansion House against damage caused by ground movements due to the Docklands Light Railway extension
.
Proc. Instn Civ. Engrs – Geotech. Engng
107
,
No. 2
,
65
76
, .
Giardina
,
G.
,
DeJong
,
M. J.
&
Mair
,
R. J.
(
2015a
).
Interaction between surface structures and tunnelling in sand: centrifuge and computational modelling
.
Tunn. Undergr. Space Technol.
50
,
465
478
, .
Giardina
,
G.
,
Hendriks
,
M. A.
&
Rots
,
J. G.
(
2015b
).
Sensitivity study on tunnelling induced damage to a masonry facade
.
Engng Struct.
89
,
111
129
, .
Goh
,
K.
&
Mair
,
R.
(
2011
).
Building damage assessment for deep excavations in Singapore and the influence of building stiffness
.
Geotech. Engng J. SEAGS & AGSSEA
42
,
No. 3
,
1
12
.
Goh
,
K.
&
Mair
,
R.
(
2012
). The response of buildings to movements induced by deep excavations. In
Geotechnical aspects of underground construction in soft ground
(ed.
G.
Viggiani
), pp.
903
910
.
Boca Raton, FL, USA
:
CRC Press
.
Haigh
,
S. K.
&
Madabhushi
,
S. G.
(
2002
). Dynamic centrifuge modelling of the destruction of Sodom and Gomorrah. In
Physical modelling in geotechnics – ICPMG '02
(eds
P.
Guo
,
R.
Phillips
and
R.
Popescu
), pp.
507
512
.
Boca Raton, FL, USA
:
CRC Press
.
Hansmire
,
W. H.
&
Cording
,
E. J.
(
1985
).
Soil tunnel test section: case history summary
.
J. Geotech. Engng
111
,
No. 11
,
1301
1320
.
Liu
,
G.
,
Houlsby
,
G.
&
Augarde
,
C.
(
2001
).
2-dimensional analysis of settlement damage to masonry buildings caused by tunnelling
.
The Struct. Engr
79
,
No. 1
,
19
25
.
Loganathan
,
N.
,
Poulos
,
H.
&
Stewart
,
D.
(
2000
).
Centrifuge model testing of tunnelling-induced ground and pile deformations
.
Géotechnique
50
,
No. 3
,
283
294
, .
Lu
,
Y.
,
Bloodworth
,
A. G.
&
Gleig
,
F.
(
2001
). Behaviour of long structures in response to tunnelling. In
Response of buildings to excavation induced ground movements, proceedings of the international conference held at Imperial College, London, UK
(ed.
F. M.
Jardine
),
Special Publication 201
, pp.
367
373
.
London, UK
:
CIRIA
.
Madabhushi
,
S.
,
Houghton
,
N.
&
Haigh
,
S.
(
2006
). A new automatic sand pourer for model preparation at University of Cambridge. In
Physical modelling in geotechnics
(eds
C. W. W.
Ng
,
Y. H.
Wang
and
L. M.
Zhang
), pp.
217
222
.
Boca Raton, FL, USA
:
CRC Press
.
Mair
,
R.
(
2013
). Tunnelling and deep excavations: Ground movements and their effects. In
Proceedings of the 15th European conference on soil mechanics and geotechnical engineering, geotechnics of hard soils – weak rocks
(eds
A.
Anagnostopoulos
,
M.
Pachakis
and
Ch.
Tsatsanifos
),
part 4
, pp.
39
70
.
Amsterdam, the Netherlands
:
IOS Press
.
Mair
,
R. J.
&
Taylor
,
R. N.
(
1997
). Theme lecture: bored tunneling in the urban environment. In
Proceedings of the 14th international conference on soil mechanics and foundation engineering, Hamburg, 6–12 September 1997
, pp.
2353
2385
.
Rotterdam, the Netherlands
:
Balkema
.
Mair
,
R.
&
Taylor
,
R.
(
2001
). Settlement predictions for Neptune, Murdoch, and Clegg Houses and adjacent masonry walls. In
Building response to tunnelling: case studies from construction of the Jubilee Line Extension, London, volume 1: projects and methods
(eds
J. B.
Burland
,
J. R.
Standing
and
F. M.
Jardine
), pp.
217
228
.
London, UK
:
Thomas Telford
.
Mair
,
R.
,
Taylor
,
R.
&
Burland
,
J.
(
1996
). Prediction of ground movements and assessment of risk of building damage due to bored tunnelling. In
Proceedings of the 4th international symposium on geotechnical aspects of underground construction in soft ground
(ed.
R. J.
Mair
), pp.
713
718
.
Rotterdam, the Netherlands
:
Balkema
.
Marshall
,
A.
,
Farrell
,
R.
,
Klar
,
A.
&
Mair
,
R.
(
2012
).
Tunnels in sands: the effect of size, depth and volume loss on greenfield displacements
.
Géotechnique
62
,
No. 5
,
385
399
, http://dx.doi.org/10.1680/geot.10.P.047.
Melis
,
M.
&
Rodriguez Ortiz
,
J.
(
2001
). Consideration of the stiffness of buildings in the estimation of subsidence damage by EPB tunnelling in the Madrid Subway. In
Response of buildings to excavation induced ground movements, proceedings of the international conference held at Imperial College, London, UK
(ed.
F. M.
Jardine
),
Special Publication 201
, pp.
387
394
.
London, UK
:
CIRIA
.
Peck
,
R. B.
(
1969
). Deep excavations and tunnelling in soft ground.
Proceedings of the 7th international conference on soil mechanics and foundation engineering
,
Mexico City, Mexico
, pp.
225
290
.
Potts
,
D.
&
Addenbrooke
,
T.
(
1997
).
A structure's influence on tunnelling induced ground movements
.
Proc. Instn Civ. Engrs – Geotech. Engng
125
,
No. 2
,
109
125
, http://dx.doi.org/10.1680/igeng.1997.29233.
Ritter
,
S.
,
Giardina
,
G.
,
DeJong
,
M. J.
&
Mair
,
R. J.
(
2017
).
Centrifuge modelling of building response to tunnel excavation
.
Int. J. Phys. Model. Geotech.
, .
Schmidt
,
B.
(
1969
).
Settlements and ground movements associated with tunneling in soil
.
PhD thesis
,
University of Illinois
,
Urbana-Champaign, IL, USA
.
Son
,
M.
&
Cording
,
E. J.
(
2007
).
Evaluation of building stiffness for building response analysis to excavation-induced ground movements
.
J. Geotech. Geoenviron. Engng
133
,
No. 8
,
995
1002
.
Standing
,
J.
(
2001
). Elizabeth House, Waterloo. In
Building response to tunnelling: case studies from construction of the Jubilee Line Extension London, volume 2: case studies
(eds
J. B.
Burland
,
J. R.
Standing
and
F. M.
Jardine
), pp.
735
754
.
London, UK
:
Thomas Telford
.
Taylor
,
R.
&
Grant
,
R.
(
1998
). Centrifuge modelling of the influence of surface structures on tunnelling induced ground movements. In
Tunnels and metropolises
(eds
A.
Negro (Jr)
and
A. A.
Ferreira
), pp.
261
266
.
Rotterdam, the Netherlands
:
Balkema
.
Viggiani
,
G.
&
Standing
,
J.
(
2001
). The treasury. In
Building response to tunnelling: case studies from construction of the Jubilee Line Extension London, volume 2: case studies
(eds
J. B.
Burland
,
J. R.
Standing
and
F. M.
Jardine
), pp.
401
432
.
London, UK
:
Thomas Telford
.
Vorster
,
T.
(
2002
).
The effects of tunnelling on buried pipes
.
PhD thesis
,
University of Cambridge
,
Cambridge, UK
.
White
,
D.
,
Take
,
W.
&
Bolton
,
M.
(
2003
).
Soil deformation measurement using particle image velocimetry (PIV) and photogrammetry
.
Géotechnique
53
,
No. 7
,
619
632
, http://dx.doi.org/10.1680/geot.2003.53.7.619.

Discussion on this paper closes on 1 March 2018, for further details see p. ii.

This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

or Create an Account

Close Modal
Close Modal