A series of full-scale experiments was conducted to estimate lateral soil constraints on pipes buried in dense sandy slopes at different burial depths. The experimental data indicated that the soil force on the pipe increases with increase in the slope grade and burial depth ratio. The lateral soil force against relative pipe displacement response observed from the experiments is presented and compared to those arising from level ground conditions. The study was extended to larger burial depth ratios by simulating pipes under sloping ground conditions using a numerical (finite-element) model that was initially calibrated using the results from physical modelling. The findings from the study in terms of the variation of peak lateral soil restraint as a function of the slope grade and burial depth ratio are presented for consideration in pipeline design.
Article navigation
May 2023
Research Article|
December 13 2021
Lateral force–displacement response of buried pipes in slopes
Mark Katebi;
Mark Katebi
*Department of Civil Engineering, University of Manitoba, Winnipeg, MB, Canada.
Search for other works by this author on:
Dharma Wijewickreme;
Dharma Wijewickreme
†Department of Civil Engineering, University of British Columbia, Vancouver, BC, Canada.
Search for other works by this author on:
Pooneh Maghoul
;
Pooneh Maghoul
‡Department of Civil, Geological and Mining Engineering, Polytechnique Montréal, QC, Canada; also Department of Civil Engineering, University of Manitoba, Winnipeg, MB, Canada (Orcid:0000-0003-0457-3968).
Search for other works by this author on:
Kshama Roy
Kshama Roy
§Northern Crescent Inc., Calgary, Alberta, Canada.
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
April 15 2021
Accepted:
September 23 2021
Online ISSN: 1751-7656
Print ISSN: 0016-8505
© 2021 Thomas Telford Ltd
2021
Geotechnique (2023) 73 (5): 375–387.
Article history
Received:
April 15 2021
Accepted:
September 23 2021
Citation
Katebi M, Wijewickreme D, Maghoul P, Roy K (2023), "Lateral force–displacement response of buried pipes in slopes". Geotechnique, Vol. 73 No. 5 pp. 375–387, doi: https://doi.org/10.1680/jgeot.21.00057
Download citation file:
New and popular articles
Suggested Reading
Performance of a buried pipeline along the dip of a slope experiencing accidental sliding
Geotechnique (February,2018)
On the effectiveness of slope-stabilising piles for soils with distinct strain-softening behaviour
Geotechnique (November,2020)
Frequency effects in the dynamic lateral stiffness of monopiles in sand: insight from field tests and 3D FE modelling
Geotechnique (July,2020)
Numerical modelling of the long-term cyclic response of laterally loaded piles driven in sands using the high-cycle accumulation framework
Geotechnique (July,2025)
Passive soil pressure on sloping ground and design of retaining structures for slope stabilisation
Geotechnique (June,2015)
Related Chapters
Finite-element modelling for the assessment of tunnel-induced damage to a masonry building
Tunnelling in the Urban Environment: Géotechnique Symposium in Print 2017
Rainfall-induced slope failure considering variability of soil properties
Risk and Variability in Geotechnical Engineering
Characterisation of model uncertainties for laterally loaded rigid drilled shafts
Risk and Variability in Geotechnical Engineering
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.