This paper presents the effects of raising the temperature of soft Bangkok clay, up to 90°C, in combination with the performance of prefabricated vertical drains (PVD) during the preloading process called thermo-PVD, as measured in laboratory model tests. For both reconstituted and undisturbed specimens, higher settlements were observed for the soil specimens with thermo-PVD loaded with constant vertical stress. Furthermore, using thermo-PVD, Kh/Ks decreased while the coefficient of horizontal consolidation Ch increased for both the undisturbed and reconstituted specimens, which resulted in an increased rate of consolidation. This behaviour can be attributed to an increase in the hydraulic conductivity of the soil as the soil temperature increased within the smear zone surrounding the PVD. Therefore, using thermo-PVD, which combines a heat source and drainage with the PVD, the drainage performance can be enhanced by reducing the drainage retardation effects in the smear zone around the thermo-PVD.
Article navigation
November 2008
Research Article|
November 01 2008
Reduction of smear effects around PVD using thermo-PVD
C. Pothiraksanon;
C. Pothiraksanon
Geotechnical and Geoenvironmental Engineering, School of Engineering and Technology, Asian Institute of Technology
Pathumthani, Thailand
Search for other works by this author on:
J. Saowapakpiboon;
J. Saowapakpiboon
Geotechnical and Geoenvironmental Engineering, School of Engineering and Technology, Asian Institute of Technology
Pathumthani, Thailand
Search for other works by this author on:
D. T. Bergado;
D. T. Bergado
Geotechnical and Geoenvironmental Engineering, School of Engineering and Technology, Asian Institute of Technology
Pathumthani, Thailand
Search for other works by this author on:
N. Y. Than
N. Y. Than
Geotechnical and Geoenvironmental Engineering, School of Engineering and Technology, Asian Institute of Technology
Pathumthani, Thailand
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
February 22 2007
Accepted:
February 20 2008
Online ISSN: 1755-0769
Print ISSN: 1755-0750
© 2008 Thomas Telford Ltd
2008
Proceedings of the Institution of Civil Engineers - Ground Improvement (2008) 161 (4): 179–187.
Article history
Received:
February 22 2007
Accepted:
February 20 2008
Citation
Pothiraksanon C, Saowapakpiboon J, Bergado DT, Than NY (2008), "Reduction of smear effects around PVD using thermo-PVD". Proceedings of the Institution of Civil Engineers - Ground Improvement, Vol. 161 No. 4 pp. 179–187, doi: https://doi.org/10.1680/grim.2008.161.4.179
Download citation file:
New and popular articles
Suggested Reading
Effects of test conditions on shear behaviour of composite soil
Proceedings of the Institution of Civil Engineers - Geotechnical Engineering (June,2012)
Stress history profiling in soils using OCD–G anisotropy relationship
Proceedings of the Institution of Civil Engineers - Geotechnical Engineering (October,2014)
Shrinkage stresses in concrete using a new material parameter
Proceedings of the Institution of Civil Engineers - Construction Materials (June,2011)
Rheological properties of oil well cement slurries
Proceedings of the Institution of Civil Engineers - Construction Materials (February,2012)
Strength correlations of cement-mixed soils using data mapping
Proceedings of the Institution of Civil Engineers - Ground Improvement (February,2014)
Related Chapters
Tunnelling
The Essence of Geotechnical Engineering: 60 years of Géotechnique
Analysis of progressive failure and cracking in old British dams
Selected papers on geotechnical engineering by P R Vaughan
Moorgate Shaft Base Slab, design, detailing and construction
Crossrail Project: Infrastructure design and construction
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
