Skip to Main Content
Article navigation

This paper reports data on the use of the prTS 12390-12 accelerated carbonation test (reference method) over the past two decades and shows that accelerated carbonation testing is a suitable technique for ranking concretes in their carbonation resistance. Testing at 5, 7 and 10 weeks provides the optimum solution that minimises the risk of incorrect ranking of different constituent materials. Analysis of data from previous studies also shows that the reference test conditions of a partial pressure of 4% carbon dioxide are a suitable level which allows sufficient carbonation to take place for accurate depth measurement while the preconditioning period of 28 days standard followed by 2 weeks drying in laboratory air did not disadvantage pozzolanic and similar type cements.