Two reinforced concrete external beam—column connection specimens were subjected to a series of slow load reversals to simulate seismic effects. Strain distributions were measured using internally strain gauged reinforcement. Specimen C3S, with a 210 mm deep beam, failed after 12 load cycles due to a plastic hinge which developed in the beam at the face of the column; specimen C9S, with a 300 mm deep beam, failed after 10 load cycles due to plastic hinges which developed in the column above and below the beam. Strains of over 17000 microstrain were recorded at the beam hinge in C3S; those in the column hinges of C9S were over 5000 microstrain. Large residual strains were also observed when the load was reversed. Peak bond stresses of∼ 5 N/mm2 were recorded early in each test, but the considerable disintegration of the connection zone caused by the load cycling resulted in an almost complete loss of bond in the connection zones by the end of each test.
Article navigation
March 1991
Research Article|
March 01 1991
A preliminary investigation of strains in reinforced concrete beam—column connections due to seismic loading
R. H. Scott, BSc(Eng), MSc, DIC, PhD, FIStructE
University of Durham
Search for other works by this author on:
*
School of Engineering and Applied Science, University of Durham, South Road, Durham DHI 3LE, UK.
Publisher: Emerald Publishing
Online ISSN: 1751-763X
Print ISSN: 0024-9831
© 1991 Thomas Telford Ltd
1991
Magazine of Concrete Research (1991) 43 (154): 59–64.
Citation
Scott RH (1991), "A preliminary investigation of strains in reinforced concrete beam—column connections due to seismic loading". Magazine of Concrete Research, Vol. 43 No. 154 pp. 59–64, doi: https://doi.org/10.1680/macr.1991.43.154.59
Download citation file:
81
Views
New and popular articles
Suggested Reading
Editorial
Structural Concrete (September,2007)
2007 reviewers
Structural Concrete (December,2007)
Editorial
Structural Concrete (December,2009)
2009 reviewers
Structural Concrete (December,2009)
Editorial
Structural Concrete (March,2007)
Related Chapters
A new assessment model for shear in reinforced concrete bridges with short anchorage lengths
Bridge Management 5: Inspection, maintenance, assessment and repair: Proceedings of the 5th International Conference on Bridge Management, organized by the University of Surrey, 11–13 April 2005
COMPARISON BETWEEN MIX PROPORTIONS METHODS ON CONCRETE RESISTANCE TO CHEMICAL DEGRADATION
Repair and Renovation of Concrete Structures: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–6 My 2005
CHLORIDE CONCENTRATION OF 25-YEAR-OLD CONCRETE
Application of Codes, Design and Regulations: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.