Sleeved bolt beam-to-column connections have been used in the precast concrete industry for many years. They have advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under shear loading. The study reported in this paper was undertaken to elucidate the behaviour of such joints under symmetrical vertical loading. Two series of full-scale tests were preformed on sample columns for which the column geometry and bolt arrangements conformed with successful commercial practice. The first series of tests was used to investigate the influence of bolt density on the ultimate load, failure mode and stiffness of such connections. The second test series showed the influence of varying concrete strength and the effectiveness of the confining reinforcement. Full details of these test programmes are given. The finite element modelling technique was used to develop three-dimensional models which were calibrated against the test observations. These models subsequently provided complete stress and deformation distributions within the joint components at intervals up to the ultimate load, and are the subject of another paper.
Article navigation
June 1995
Research Article|
June 01 1995
An experimental study of the behaviour of sleeved bolt connections in precast concrete frames
C. K. Jolly
University of Southampton
Search for other works by this author on:
*
University of southampton, southampton SO9 5NH, UK.
Publisher: Emerald Publishing
Online ISSN: 1751-763X
Print ISSN: 0024-9831
© 1995 Thomas Telford Ltd
1995
Magazine of Concrete Research (1995) 47 (171): 119–127.
Citation
Mohamed SAM, Jolly CK (1995), "An experimental study of the behaviour of sleeved bolt connections in precast concrete frames". Magazine of Concrete Research, Vol. 47 No. 171 pp. 119–127, doi: https://doi.org/10.1680/macr.1995.47.171.119
Download citation file:
Suggested Reading
Modelling bond strength of corroded plain bar reinforcement in concrete
Structural Concrete (September,2007)
The use of prestressed concrete piles to support integral abutments
Structural Concrete (September,2007)
Concrete members with plate reinforcement: mechanical bond analysis
Structural Concrete (December,2007)
Bond behaviour of NSM FRP strips in service
Structural Concrete (September,2008)
Failure analysis of a thin-webbed girder of post-tensioned concrete
Structural Concrete (March,2006)
Related Chapters
A new assessment model for shear in reinforced concrete bridges with short anchorage lengths
Bridge Management 5: Inspection, maintenance, assessment and repair: Proceedings of the 5th International Conference on Bridge Management, organized by the University of Surrey, 11–13 April 2005
COMPARISON BETWEEN MIX PROPORTIONS METHODS ON CONCRETE RESISTANCE TO CHEMICAL DEGRADATION
Repair and Renovation of Concrete Structures: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–6 My 2005
CHLORIDE CONCENTRATION OF 25-YEAR-OLD CONCRETE
Application of Codes, Design and Regulations: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.