This paper reports results of a study conducted to evaluate plastic shrinkage cracking of concrete made with varying dosages of several pozzolanic materials, such as fly ash (20, 30 and 40%), silica fume (5, 10 and 15%) and blastfurnace slag (50, 60 and 70%). These concrete specimens were exposed to hot—humid and hot—dry environments. The effect of these environmental conditions on plastic shrinkage cracking was evaluated. The rate of water evaporation in the blended cement concrete specimens was noted to be more than that in the plain cement concrete specimens. Further, bleeding in the blended cement concrete specimens was less than that in plain cement concrete specimens. The cumulative effect of these two parameters resulted in increased plastic shrinkage cracking of the blended cement concretes. Although cracks were observed earlier in the plain cement concrete specimens than in the blended cement concrete specimens, the total area of cracks in the latter cements was more than that in the former cements. The results of this study also indicate that relative humidity influences plastic shrinkage cracking of concrete significantly in comparison with the effect of the type of cement.
Article navigation
August 1999
Research Article|
August 01 1999
Plastic shrinkage cracking of blended cement concretes in hot environments Available to Purchase
A. A. Almussalam;
King Fahd University of Petroleum and Minerals
Search for other works by this author on:
M. Maslehuddin;
King Fahd University of Petroleum and Minerals
Search for other works by this author on:
M. Abdul-Waris;
M. Abdul-Waris
King Fahd University of Petroleum and Minerals
Search for other works by this author on:
F. H. Dakhil;
King Fahd University of Petroleum and Minerals
Search for other works by this author on:
O. S. B. Al-Amoudi
King Fahd University of Petroleum and Minerals
Search for other works by this author on:
*
King Fand University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia.
Publisher: Emerald Publishing
Online ISSN: 1751-763X
Print ISSN: 0024-9831
© 1999 Thomas Telford Ltd
1999
Magazine of Concrete Research (1999) 51 (4): 241–246.
Citation
Almussalam AA, Maslehuddin M, Abdul-Waris M, Dakhil FH, Al-Amoudi OSB (1999), "Plastic shrinkage cracking of blended cement concretes in hot environments". Magazine of Concrete Research, Vol. 51 No. 4 pp. 241–246, doi: https://doi.org/10.1680/macr.1999.51.4.241
Download citation file:
Suggested Reading
Editorial
Structural Concrete (September,2007)
2007 reviewers
Structural Concrete (December,2007)
Editorial
Structural Concrete (December,2009)
2009 reviewers
Structural Concrete (December,2009)
Editorial
Structural Concrete (March,2007)
Related Chapters
A new assessment model for shear in reinforced concrete bridges with short anchorage lengths
Bridge Management 5: Inspection, maintenance, assessment and repair: Proceedings of the 5th International Conference on Bridge Management, organized by the University of Surrey, 11–13 April 2005
COMPARISON BETWEEN MIX PROPORTIONS METHODS ON CONCRETE RESISTANCE TO CHEMICAL DEGRADATION
Repair and Renovation of Concrete Structures: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–6 My 2005
CHLORIDE CONCENTRATION OF 25-YEAR-OLD CONCRETE
Application of Codes, Design and Regulations: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
