This article reports on the structural behaviour of shear-deficient reinforced concrete beams repaired with Slurry Infiltrated Fibre Concrete (SIFCON), and proposes a simple analytical procedure for predicting the shear capacity of the repaired beams. SIFCON is made by pre-placing short, discontinuous steel fibres into the form, followed by infiltrating the fibres with cement-based slurry. A series of 14 shear-deficient reinforced concrete rectangular beams was tested under third-point loading to study the effectiveness of using externally applied SIFCON jackets as a method of increasing the beams' shear capacity. The parameters investigated included the shear span-to-effective depth ratio (a/d), amount of longitudinal reinforcement (ρ) and the thickness of the jacket (t). For the range of variables tested, the results indicate that all the beams failed in shear tests and those repaired with SIFCON displayed an excellent shear capacity. The use of SIFCON jackets as external shear reinforcement eliminated the brittle shear failure and increased the ultimate shear strength of the repaired beams from 25–55%. This indicates that SIFCON may be considered as a promising material for design–maintain–rehabilitate programme of concrete structures.
Article navigation
December 2001
Research Article|
December 01 2001
Structural repair of shear-deficient reinforced concrete beams using SIFCON
M. J. Shannag;
M. J. Shannag
*
Department of Civil Engineering, Jordan University of Science and Technology
Irbid-22110, Jordan
Search for other works by this author on:
S. Barakat;
S. Barakat
†
Department of Civil Engineering, University of Sharjah
PO Box 27272, Sharjah-UAE
Search for other works by this author on:
F. Jaber
F. Jaber
*
Department of Civil Engineering, Jordan University of Science and Technology
Irbid-22110, Jordan
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
September 27 2000
Revision Received:
April 25 2001
Accepted:
July 02 2001
Online ISSN: 1751-763X
Print ISSN: 0024-9831
© 2001 Thomas Telford Ltd
2001
Magazine of Concrete Research (2001) 53 (6): 391–403.
Article history
Received:
September 27 2000
Revision Received:
April 25 2001
Accepted:
July 02 2001
Citation
Shannag MJ, Barakat S, Jaber F (2001), "Structural repair of shear-deficient reinforced concrete beams using SIFCON". Magazine of Concrete Research, Vol. 53 No. 6 pp. 391–403, doi: https://doi.org/10.1680/macr.2001.53.6.391
Download citation file:
Suggested Reading
Editorial
Structural Concrete (September,2007)
2007 reviewers
Structural Concrete (December,2007)
Editorial
Structural Concrete (December,2009)
2009 reviewers
Structural Concrete (December,2009)
Editorial
Structural Concrete (March,2007)
Related Chapters
A new assessment model for shear in reinforced concrete bridges with short anchorage lengths
Bridge Management 5: Inspection, maintenance, assessment and repair: Proceedings of the 5th International Conference on Bridge Management, organized by the University of Surrey, 11–13 April 2005
COMPARISON BETWEEN MIX PROPORTIONS METHODS ON CONCRETE RESISTANCE TO CHEMICAL DEGRADATION
Repair and Renovation of Concrete Structures: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–6 My 2005
CHLORIDE CONCENTRATION OF 25-YEAR-OLD CONCRETE
Application of Codes, Design and Regulations: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
