This experimental investigation was conducted to examine the behaviour of eight one-third scale columns made of high-strength concrete. The columns were subjected to a constant axial load corresponding to 30% of the column axial load capacity and a cyclic horizontal load-inducing reversed bending moment. The variables studied in this research are the volumetric ratio of transverse reinforcement (ρs = 1·58, 2·25%), tie configuration (Type H, Type C, Type D) and tie yield strength (fyh = 548·8 and 779·1 MPa). Test results show that the flexural strength of all the columns exceeds calculated flexural capacities based on the equivalent concrete stress block used in the current design code. Columns with 42% higher amounts of transverse reinforcement than that required by seismic provisions of ACI 318-02 showed ductile behaviour. With an axial load of 3% of the axial load capacity, it is recommended that the yield strength of transverse reinforcement be held equal to or below 548·8 MPa. Relationships between the calculated damage index and the observed damage such as initial crack, spalling of concrete, buckling of longitudinal bar, and crushing of concrete are proposed.
Article navigation
June 2005
Research Article|
June 01 2005
Seismic performance of high-strength concrete columns Available to Purchase
S.-K. Hwang;
S.-K. Hwang
*
Department of Architecture, Woosong University
Daejeon 300-718, South Korea
Search for other works by this author on:
H.-D. Yun;
H.-D. Yun
*
Department of Architecture, Woosong University
Daejeon 300-718, South Korea
Search for other works by this author on:
W.-S. Park;
W.-S. Park
†
School of Architecture, Chungnam National University
Daejeon 305-764, South Korea
Search for other works by this author on:
B.-C. Han
B.-C. Han
†
School of Architecture, Chungnam National University
Daejeon 305-764, South Korea
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
July 24 2003
Revision Received:
February 23 2004
Accepted:
April 30 2004
Online ISSN: 1751-763X
Print ISSN: 0024-9831
© 2005 Thomas Telford Ltd
2005
Magazine of Concrete Research (2005) 57 (5): 247–260.
Article history
Received:
July 24 2003
Revision Received:
February 23 2004
Accepted:
April 30 2004
Citation
Hwang S, Yun H, Park W, Han B (2005), "Seismic performance of high-strength concrete columns". Magazine of Concrete Research, Vol. 57 No. 5 pp. 247–260, doi: https://doi.org/10.1680/macr.2005.57.5.247
Download citation file:
Suggested Reading
Editorial
Structural Concrete (September,2007)
2007 reviewers
Structural Concrete (December,2007)
Editorial
Structural Concrete (December,2009)
2009 reviewers
Structural Concrete (December,2009)
Editorial
Structural Concrete (March,2007)
Related Chapters
LIGHT WEIGHT CONCRETE APPLICATION IN BRIDGES
Concrete for Transportation Infrastructure: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
CONCRETE FOOTBRIDGES
Concrete for Transportation Infrastructure: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
A new assessment model for shear in reinforced concrete bridges with short anchorage lengths
Bridge Management 5: Inspection, maintenance, assessment and repair: Proceedings of the 5th International Conference on Bridge Management, organized by the University of Surrey, 11–13 April 2005
Recommended for you