The effect of shear deformation is not negligible, in particular for reinforced concrete beams with thin webs and low span-to-depth ratios. However, this contribution to deflection is often neglected because there are no suitable models for everyday applications. On the basis of a theoretical formulation proposed by the authors for the calculation of shear strain in service conditions, the paper offers a theoretical interpretation of some beam tests, highlights the shear contribution to deflection and examines the main aspects of an extensive parametric analysis considering the main parameters involved. The results of the analysis have allowed the most common cases in which the influence of shear on deflection becomes significant to be identified. They represent an effective tool for the direct evaluation of this contribution.
Article navigation
April 2012
Research Article|
April 01 2012
Parametric analysis of the influence of shear on the deflection of RC beams in service Available to Purchase
Pier Giorgio Debernardi;
Pier Giorgio Debernardi
Professor, Department of Structural and Geotechnical Engineering, Politecnico di Torino, Turin, Italy
Search for other works by this author on:
Matteo Guiglia;
Matteo Guiglia
Research Fellow, Department of Structural and Geotechnical Engineering, Politecnico di Torino, Turin, Italy
Search for other works by this author on:
Maurizio Taliano
Maurizio Taliano
Assistant Professor, Department of Structural and Geotechnical Engineering, Politecnico di Torino, Turin, Italy
Search for other works by this author on:
Publisher: Emerald Publishing
Revision Received:
January 20 2011
Revision Requested:
March 22 2011
Accepted:
March 25 2011
Online ISSN: 1751-763X
Print ISSN: 0024-9831
ICE Publishing: All rights reserved
2012
Magazine of Concrete Research (2012) 64 (4): 335–350.
Article history
Revision Received:
January 20 2011
Revision Requested:
March 22 2011
Accepted:
March 25 2011
Citation
Debernardi PG, Guiglia M, Taliano M (2012), "Parametric analysis of the influence of shear on the deflection of RC beams in service". Magazine of Concrete Research, Vol. 64 No. 4 pp. 335–350, doi: https://doi.org/10.1680/macr.11.00013
Download citation file:
Suggested Reading
Modelling bond strength of corroded plain bar reinforcement in concrete
Structural Concrete (September,2007)
The use of prestressed concrete piles to support integral abutments
Structural Concrete (September,2007)
Concrete members with plate reinforcement: mechanical bond analysis
Structural Concrete (December,2007)
Bond behaviour of NSM FRP strips in service
Structural Concrete (September,2008)
Failure analysis of a thin-webbed girder of post-tensioned concrete
Structural Concrete (March,2006)
Related Chapters
MORE SUSTAINABLE CONSTRUCTION: THE ROLE OF CONCRETE
Challenges of Concrete Construction: Volume 5, Sustainable Concrete Construction: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 9–11 September 2002
THE CONDITIONS OF THAUMASITE FORMATION AND ITS ROLE IN CONCRETE
Challenges of Concrete Construction: Volume 6, Concrete for Extreme Conditions: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 9–11 September 2002
ASSESSMENT OF FIRE DAMAGE OF CONCRETE BY USING INFRARED THERMAL IMAGING METHOD
Challenges of Concrete Construction: Volume 6, Concrete for Extreme Conditions: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 9–11 September 2002
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.