It has been demonstrated that high-strength concrete (HSC) is able to improve the strength-to-weight ratio of reinforced concrete columns and maximise the usable areas of tall buildings. However, closely spaced transverse reinforcement needs to be installed to provide stronger confinement for averting brittle failure of HSC. To resolve the problem, double-skinned concrete-filled-steel-tubular (CFST) columns have been advocated, which eliminates the steel congestion problem for better concrete placing and reduces the concrete arching action thus providing a more uniform confining pressure. Despite these advantages, a major shortcoming of double-skinned CFST columns is that imperfect interface bonding occurs in the elastic stage that reduces elastic strength and stiffness. Thus, the authors proposed to adopt external confinement to restrict the lateral dilation of the outer tube of double-skinned CFST columns. To verify the effectiveness of the proposed external rings, a total of 20 double-skinned normal- and high-strength CFST columns were tested. From the test results, it was observed that the stiffness, axial load-carrying capacity and ductility of ring-confined double-skinned CFST columns were significantly higher than the unconfined columns.
Article navigation
October 2013
Research Article|
October 01 2013
Improving interface bonding of double-skinned CFST columns
Chunxiao Dong;
Chunxiao Dong
MPhil Student, Department of Civil Engineering, The University of Hong Kong, Hong Kong
Search for other works by this author on:
Johnny Ching Ming Ho
Johnny Ching Ming Ho
Senior Lecturer, School of Civil Engineering, The University of Queensland, Brisbane, Australia
Search for other works by this author on:
Publisher: Emerald Publishing
Revision Received:
February 20 2013
Revision Requested:
April 30 2013
Accepted:
July 17 2013
Online ISSN: 1751-763X
Print ISSN: 0024-9831
ICE Publishing: All rights reserved
2013
Magazine of Concrete Research (2013) 65 (20): 1199–1211.
Article history
Revision Received:
February 20 2013
Revision Requested:
April 30 2013
Accepted:
July 17 2013
Citation
Dong C, Ho JCM (2013), "Improving interface bonding of double-skinned CFST columns". Magazine of Concrete Research, Vol. 65 No. 20 pp. 1199–1211, doi: https://doi.org/10.1680/macr.13.00041
Download citation file:
New and popular articles
Suggested Reading
Lap splice over a grouted joint in a lattice girder system
Magazine of Concrete Research (December,2007)
An apparatus for testing the response of small specimens to controlled environmental changes
Magazine of Concrete Research (September,1982)
The deformation of a rectangular slab stiffened by beams under transverse loads
Magazine of Concrete Research (July,1962)
The moisture movement of natural aggregate and its effect on concrete
Magazine of Concrete Research (July,1962)
The rotation of reinforced concrete plastic hinges at ultimate load
Magazine of Concrete Research (July,1962)
Related Chapters
CONTRIBUTION OF MIXED CEMENTS IN PRODUCTION OF MORE DURABLE AND SUSTAINABLE CONCRETE
Achieving Sustainability in Construction: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–6 July 2005
THE EFFECT OF GAS PATH LENGTH ON THE MEASURED PERMEABILITY OF CONCRETE
Cement Combinations for Durable Concrete: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
ALKALI-SILICA REACTION OF CONCRETE CONTAINING GLASS - INTERACTION WITH REACTIVE AGGREGATES
Cement Combinations for Durable Concrete: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.