For reinforced concrete flat slab structures, column failure due to unexpected extreme loading may significantly increase the moment and shear force at adjacent slab–column connections, which can trigger punching shear failure at these connections and result in progressive collapse of flat slab structures. To determine the possible load-resisting mechanisms developed in flat slab structures in resisting progressive collapse, three multi-panel flat slab substructures are tested in this study. A flat slab substructure is tested as a control specimen. The remaining two specimens are strengthened by adding drop panels or post-installed shear bolts. Punching shear failure is observed in the control specimen and the specimen with post-installed shear bolts after reaching their yield loads. However, even the control specimen without any strengthening exhibited considerable post-failure resistance and deformation capacity mainly due to sufficient integrity reinforcement, which had been installed in the bottom of the slab. Test results indicated that drop panels not only increase the flexural resistance but also raise the punching shear resistance of the connections significantly. Thus, no obvious punching shear failure is observed in the specimen with drop panels. However, post-installed shear bolts can only increase the punching shear resistance. For post-failure behaviour, this is not very effective. The test results demonstrated that flexural failure dominates the performance of test specimens, as relatively low slab reinforcement ratio but high span/thickness ratio was designed.
Article navigation
April 2015
Research Article|
April 01 2015
Load-resisting mechanism to mitigate progressive collapse of flat slab structures Available to Purchase
Kai Qian;
Kai Qian
School of Civil and Environmental Engineering, Nanyang Technological University, Singapore
Search for other works by this author on:
Bing Li
Bing Li
School of Civil and Environmental Engineering, Nanyang Technological University, Singapore
Search for other works by this author on:
Publisher: Emerald Publishing
Revision Received:
September 09 2014
Revision Requested:
October 30 2014
Accepted:
November 12 2014
Online ISSN: 1751-763X
Print ISSN: 0024-9831
ICE Publishing: All rights reserved
2015
Magazine of Concrete Research (2015) 67 (7): 349–363.
Article history
Revision Received:
September 09 2014
Revision Requested:
October 30 2014
Accepted:
November 12 2014
Citation
Qian K, Li B (2015), "Load-resisting mechanism to mitigate progressive collapse of flat slab structures". Magazine of Concrete Research, Vol. 67 No. 7 pp. 349–363, doi: https://doi.org/10.1680/macr.14.00293
Download citation file:
Suggested Reading
Editorial
Structural Concrete (September,2007)
2007 reviewers
Structural Concrete (December,2007)
Editorial
Structural Concrete (December,2009)
2009 reviewers
Structural Concrete (December,2009)
Editorial
Structural Concrete (March,2007)
Related Chapters
A new assessment model for shear in reinforced concrete bridges with short anchorage lengths
Bridge Management 5: Inspection, maintenance, assessment and repair: Proceedings of the 5th International Conference on Bridge Management, organized by the University of Surrey, 11–13 April 2005
COMPARISON BETWEEN MIX PROPORTIONS METHODS ON CONCRETE RESISTANCE TO CHEMICAL DEGRADATION
Repair and Renovation of Concrete Structures: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–6 My 2005
CHLORIDE CONCENTRATION OF 25-YEAR-OLD CONCRETE
Application of Codes, Design and Regulations: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.