The efficiency of different accelerated corrosion techniques was compared to evaluate the role of some blended cements in corrosion protection for reinforced-concrete elements exposed to chloride. Specifically, a quick impressed voltage accelerated corrosion technique was implemented and compared with slower macrocell techniques, such as southern exposure and cracked beam. For the same purpose, corrosion protection performance was also evaluated for reinforced-concrete slabs made with identical cement blends and exposed to severe freely corroding conditions for 140 weeks. Corrosion results for the impressed voltage technique were remarkably comparable to those obtained for the other, slower, corrosion techniques investigated. Therefore, instead of using more complicated techniques, the impressed voltage technique can prove reliable for assessing the chloride-induced corrosion activity of cementitious materials with noticeable differences in durability characteristics. However, further research is currently underway to verify the repeatability of the latter conclusion. Based on the impressed voltage technique, an empirical equation is proposed to predict the delay in steel corrosion initiation obtained by replacing Portland cement with blended cements. The proposed equation depends on some easily measured durability characteristics of concrete surrounding steel. Further research results and data published in the literature can be used to refine the proposed equation.
Article navigation
June 2019
Research Article|
June 22 2018
Efficiency of accelerated techniques for assessing corrosion protection of blended cements
Aladdin M. Sharkawi;
Aladdin M. Sharkawi
Visiting Professor, North Carolina State University, USA
Associate Professor, Structural Engineering Department, Faculty of Engineering, Tanta University, Tanta, Egypt (corresponding author: amsharka@hotmail.com)
Search for other works by this author on:
Ahmed M. Seyam
Ahmed M. Seyam
Graduate student, Structural Engineering Department, Faculty of Engineering, Tanta University, Tanta, Egypt
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
June 14 2017
Revision Received:
February 26 2018
Accepted:
March 16 2018
Online ISSN: 1751-763X
Print ISSN: 0024-9831
ICE Publishing: All rights reserved
2018
Magazine of Concrete Research (2019) 71 (12): 637–646.
Article history
Received:
June 14 2017
Revision Received:
February 26 2018
Accepted:
March 16 2018
Citation
Sharkawi AM, Seyam AM (2019), "Efficiency of accelerated techniques for assessing corrosion protection of blended cements". Magazine of Concrete Research, Vol. 71 No. 12 pp. 637–646, doi: https://doi.org/10.1680/jmacr.17.00269
Download citation file:
Suggested Reading
Moisture uptake in concrete under freezing–thawing exposure
Magazine of Concrete Research (December,2015)
A laboratory test on the effect of bugholes on surface degradation of tunnel lining concrete subject to freeze–thaw cycles
Magazine of Concrete Research (June,2020)
Durability of self-healing ultra-high-strength reinforced micro-concrete under freeze–thaw or chloride attack
Magazine of Concrete Research (June,2017)
Effects of fly ash on Portland limestone cement under sulfate attack at low temperature
Magazine of Concrete Research (November,2018)
Improved one-phase model of uniform corrosion for predicting the volume of rust
Magazine of Concrete Research (June,2019)
Related Chapters
Reinforced concrete bridges
ICE Manual of Bridge Engineering
DURABILITY OF MARINE AND COASTAL STREUCTURES – THE HIGH QUALITY COBER AND MONITORING APPROACH
Repair and Renovation of Concrete Structures: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–6 My 2005
EFFECT OF TEMPERATURE ON THE DURABILITY OF SYSTEM FOR STRENGTHENING OF CONCRETE STRUCTURES
Repair and Renovation of Concrete Structures: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–6 My 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
