In this research, the effect of porosity owing to foam on the penetration parameters of foamed concrete, including absorption and chloride ingress, is evaluated. The penetration parameters of foamed concrete are determined using a water/cement (w/c) ratio of 0.5 and foam contents of 20, 35 and 50%, and then compared with the base mix without foam and with an equal w/c ratio. In addition, the penetration parameters of the structural-grade foam concrete with a w/c ratio of 0.4 and foam volume of 20% are determined and compared with a conventional concrete of equal strength. The results show that, with an increase in foam porosity, the volumetric absorption and the capillary absorption coefficient are decreased, and that therefore chloride diffusion is increased. The discrepancy is owing to the presentation of absorption results based on a total concrete volume. By considering these results based on paste volume, which is the penetrable phase, absorption results show the same trend as the chloride diffusion results. Increased foam volume results in larger and more connected air voids. Meanwhile, the structural-grade foam concrete has a similar performance to the base mix, and also shows less penetrability relative to conventional concrete of equal strength.
Article navigation
October 2022
Research Article|
May 31 2022
Effect of foam volume on penetration parameters of foamed concrete
Mohammad Mahdi Rastegar
;
Mohammad Mahdi Rastegar
Graduate Researcher, Faculty of Civil Engineering, K. N. Toosi University of Technology, Tehran, Iran (corresponding author: mmrastegar@mail.kntu.ac.ir)
Search for other works by this author on:
Alireza Bagheri
Alireza Bagheri
Associate Professor, Faculty of Civil Engineering, K. N. Toosi University of Technology, Tehran, Iran
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
September 25 2021
Accepted:
March 30 2022
Online ISSN: 1751-763X
Print ISSN: 0024-9831
ICE Publishing: All rights reserved
2022
Magazine of Concrete Research (2022) 74 (19): 989–998.
Article history
Received:
September 25 2021
Accepted:
March 30 2022
Citation
Rastegar MM, Bagheri A (2022), "Effect of foam volume on penetration parameters of foamed concrete". Magazine of Concrete Research, Vol. 74 No. 19 pp. 989–998, doi: https://doi.org/10.1680/jmacr.21.00247
Download citation file:
New and popular articles
Suggested Reading
Effects of foam content on chloride ingress and steel corrosion in foamed concrete
Magazine of Concrete Research (January,2021)
Microstructure and mixture proportioning of non-structural foamed concrete with silica fume
Magazine of Concrete Research (June,2017)
High-volume, ultra-low-density fly ash foamed concrete
Magazine of Concrete Research (May,2017)
Effect of sodium sulfate and sodium nitrite on air-void system in air-entrained concrete
Magazine of Concrete Research (August,2016)
Municipal incinerated bottom ash use as a cement component in concrete
Magazine of Concrete Research (March,2017)
Related Chapters
Durability of self-healing ultra-high-strength reinforced micro-concrete under freeze–thaw or chloride attack
ICE Themes Smart Concrete
A galvanic sensor for monitoring corrosion of steel in carbonated concrete
ICE Themes Smart Concrete
Microstructure, thermal analysis and chloride penetration of self-compacting concrete under different conditions
ICE Themes Self-Compacting Concrete
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
