This paper presents an experimental and theoretical programme aimed at promoting a greater understanding of the behaviour of strip footing on oil-contaminated sand slope. Contaminated sand layers were prepared by mixing sand with an oil content of 0–3% by weight of dried sand. A broad series of conditions, including uncontaminated cases, was tested by varying parameters such as the thickness of the contaminated sand layer, the type of oil contamination, the slope angle and the edge distance of the footing relative to the slope crest. A plane-strain elastoplastic theoretical model using finite-element analyses was additionally performed to supplement the results of the model tests. The results indicate that the ultimate bearing capacity of strip footings on the contaminated sloping ground can be drastically decreased with increasing the thickness of the contaminated sand layer and the slope angle. To design a footing on oil-contaminated sand slope, it would be necessary to reduce the value of the bearing capacity factor Nγ according to the type and percentage of the contaminated oil. The investigation also provides knowledge to revise the foundation design of the existing structures subjected to contamination.
Article navigation
September 2016
Research Article|
October 12 2015
Behaviour of strip footing on oil-contaminated sand slope
Ahmed M. A. Nasr, PhD
Ahmed M. A. Nasr, PhD
Associate Professor
Structural Engineering Department, Faculty of Engineering, Tanta University, Tanta, Egypt
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
April 09 2015
Accepted:
August 11 2015
Online ISSN: 2042-6550
Print ISSN: 1346-213X
ICE Publishing: All rights reserved
2015
International Journal of Physical Modelling in Geotechnics (2016) 16 (3): 134–151.
Article history
Received:
April 09 2015
Accepted:
August 11 2015
Citation
Nasr AMA (2016), "Behaviour of strip footing on oil-contaminated sand slope". International Journal of Physical Modelling in Geotechnics, Vol. 16 No. 3 pp. 134–151, doi: https://doi.org/10.1680/jphmg.15.00014
Download citation file:
Suggested Reading
Lateral resistance of a pile installed near a reinforced slope
International Journal of Physical Modelling in Geotechnics (December,2011)
Evaluation of the bearing capacity of footings on slopes
International Journal of Physical Modelling in Geotechnics (September,2012)
A rheological model for the description of boulder impacts on granular strata
Geotechnique (September,2006)
Kinematics of soil arching in piled embankments
Geotechnique (January,2019)
Inclusion of higher-temperature effects in a soil behaviour model
Geotechnique (April,2009)
Related Chapters
Rainfall-induced slope failure considering variability of soil properties
Risk and Variability in Geotechnical Engineering
Physical modelling
The Essence of Geotechnical Engineering: 60 years of Géotechnique
Slope stability
ICE Manual of Geotechnical Engineering, Second edition, Volume I
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.