Microelectromechanical systems (MEMS) accelerometers are becoming more prevalent in geotechnical engineering and geotechnical centrifuge modelling. In centrifuge experiments these sensors have shown great promise, but still exhibit limitations. This paper proposes a new methodology for the use of single-axis, low-g, high-accuracy MEMS accelerometers to measure the orientation of an object on the vertical rotational plane of centrifugal acceleration and Earth's gravity in a geotechnical centrifuge. The method specifically compensates for the measured cross-axis acceleration by an MEMS accelerometer when in a high-g environment. This is done by determining the apparent internal misalignment of the MEMS sensing unit, relative to its packaging, from a high-g cross-axis calibration. The misalignment can then be used to correct the measured orientation of the sensor relative to a centrifuge gravity vector. When compared to simplified approaches, measurements of absolute orientation are improved by 0·89° and the standard deviation of measurements between multiple sensors is reduced by 0·71°. Overall, this new methodology significantly improves the accuracy of orientation measurements by MEMS accelerometers in the geotechnical centrifuge, opening the door to use these inexpensive sensors in more experiments.
Article navigation
September 2018
Research Article|
October 30 2017
Use of a MEMS accelerometer to measure orientation in a geotechnical centrifuge Available to Purchase
Ryan D. Beemer, PhD
;
Ryan D. Beemer, PhD
Postdoctoral Research Associate, Centre for Offshore Foundation Systems, University of Western Australia, Perth, Australia (corresponding author: ryan.beemer@uwa.edu.au)
Search for other works by this author on:
Giovanna Biscontin, PhD
;
Giovanna Biscontin, PhD
Lecturer, Department of Engineering, University of Cambridge, Cambridge, UK
Search for other works by this author on:
Madhuri Murali, PhD
;
Madhuri Murali, PhD
Project Engineer, Fugro Marine GeoServices, Inc., Houston, TX, USA
Search for other works by this author on:
Charles P. Aubeny, PhD
Charles P. Aubeny, PhD
Professor, Zachry Department of Civil Engineering, Texas A&M University, College Station, TX, USA
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
December 14 2016
Accepted:
October 02 2017
Online ISSN: 2042-6550
Print ISSN: 1346-213X
ICE Publishing: All rights reserved
2017
International Journal of Physical Modelling in Geotechnics (2018) 18 (5): 253–265.
Article history
Received:
December 14 2016
Accepted:
October 02 2017
Citation
Beemer RD, Biscontin G, Murali M, Aubeny CP (2018), "Use of a MEMS accelerometer to measure orientation in a geotechnical centrifuge". International Journal of Physical Modelling in Geotechnics, Vol. 18 No. 5 pp. 253–265, doi: https://doi.org/10.1680/jphmg.16.00077
Download citation file:
Suggested Reading
Centrifuge 2D gravity on a vertical rotational reference frame
International Journal of Physical Modelling in Geotechnics (November,2017)
Displacement and internal force control in cable-stayed bridges
Proceedings of the Institution of Civil Engineers - Bridge Engineering (August,2017)
The bearing capacity of footings on sand with a weak layer
Geotechnical Research (March,2017)
Scour downstream of aprons caused by sluices
Proceedings of the Institution of Civil Engineers - Water Management (June,2005)
Efficiency of micro piles in reinforcing embankments
Proceedings of the Institution of Civil Engineers - Ground Improvement (May,2014)
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.