Finned piles are considered a novel solution to replace large-diameter piles supporting transmission towers, bridge abutments and so on and are often implemented beneficially for mooring dolphins in offshore areas. This experimental investigation was attempted to examine the lateral response of short-finned piles installed in the proximity of a typical slope of 1V:2H. The 1g model testing of regular and finned piles at different load eccentricities comprised three lateral load tests on horizontal ground and 24 lateral load tests on the slope with the pile at varying distances from the crest. The fin efficiency was observed to decrease with an increase in load eccentricity due to the poorer mobilisation of soil resistance on fins at higher load eccentricities. The finned pile installed at a distance of two pile diameters away from the crest exhibited a net efficiency closer to unity, indicating its ability to improve the receptible subgrade reaction near a loose and steeper sandy slope. An in-depth study of soil resistance developed in the finned pile located at the crest reveals that the fins effectively reduced the soil resistance, specifically in the region above the pivot point.
Article navigation
May 2024
Research Article|
October 12 2023
Behaviour of a laterally loaded short-finned pile located on sloping ground Available to Purchase
Kaloor Thottooli Krishnanunni;
Kaloor Thottooli Krishnanunni
Research scholar, Department of Civil Engineering, NIT Tiruchirappalli, Tamil Nadu, India
Search for other works by this author on:
Deendayal Rathod
Deendayal Rathod
Associate Professor, Department of Civil Engineering, NIT Tiruchirappalli, Tamil Nadu, India (corresponding author: deendayalrathod123@gmail.com, deendayal@nitt.edu)
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
February 27 2023
Accepted:
September 07 2023
Online ISSN: 2042-6550
Print ISSN: 1346-213X
Emerald Publishing Limited: All rights reserved
2023
International Journal of Physical Modelling in Geotechnics (2024) 24 (3): 110–123.
Article history
Received:
February 27 2023
Accepted:
September 07 2023
Citation
Krishnanunni KT, Rathod D (2024), "Behaviour of a laterally loaded short-finned pile located on sloping ground". International Journal of Physical Modelling in Geotechnics, Vol. 24 No. 3 pp. 110–123, doi: https://doi.org/10.1680/jphmg.23.00011
Download citation file:
Suggested Reading
Numerical modelling of discrete pile rows for slope stability and generic guidance for design
Geotechnique (January,2010)
Lateral cyclic loading of single piles in sand
International Journal of Physical Modelling in Geotechnics (September,2003)
Group pile behavior under lateral loading in centrifuge model tests
International Journal of Physical Modelling in Geotechnics (December,2004)
Centrifuge modelling of upheaval buckling in sand
International Journal of Physical Modelling in Geotechnics (June,2001)
Physical modelling of a cantilever wall
International Journal of Physical Modelling in Geotechnics (June,2004)
Related Chapters
A generic approach to soil–structure interaction considering the effects of soil heterogeneity
Risk and Variability in Geotechnical Engineering
Rainfall-induced slope failure considering variability of soil properties
Risk and Variability in Geotechnical Engineering
Influence of soil heterogeneity on load redistribution and settlement of a hyperstatic three-support frame
Risk and Variability in Geotechnical Engineering
Recommended for you