Purpose

The purpose of this study is to investigate the influence of progressive collapse under high temperature for a reinforced concrete (RC) frame. An analytical programme was analysed for a two-bay five-storey RC frame exposed to high temperature at different column locations.

Design/methodology/approach

The effects of high temperature protections and locations (i.e. corner, middle and intermediate) on collapse conditions and load distributions were studied for the steady-state linear analysis using finite element software.

Findings

The results show that the frame will not collapse suddenly at temperatures up to 400°C. This is attributed to an increase in the deflections of the column, which increases the lateral displacement of adjacent heated columns and governs their buckling. This indicates that the temperature rating in the column against collapse can occur at a range of 500°C-600°C compared to that of individual members. The collapse pattern of RC frames designed as ordinary moment resisting frames, and under ordinary load, combinations is based on GSA guidelines. The results for displacement, stress and axial force were collected and discussed.

Originality/value

The two-bay five-storey frame has been created in finite element software, and linear analysis is used to perform this study with a different temperature.

Licensed re-use rights only
You do not currently have access to this content.
Don't already have an account? Register

Purchased this content as a guest? Enter your email address to restore access.

Please enter valid email address.
Email address must be 94 characters or fewer.
Pay-Per-View Access
$41.00
Rental

or Create an Account

Close Modal
Close Modal