This paper presents the results of an experimental and numerical study to clarify the influence of the surrounding building structure in the fire behaviour of reinforced concrete columns with restrained thermal elongation. The parameters studied were: the longitudinal reinforcement ratio, the slenderness of the column and the stiffness of the surrounding structure to the column in fire. The experimental study was complemented by a numerical study carried out using the finite element program SAFIR. Simplified calculation methods proposed in EN1992-1-2 were also used to evaluate the fire resistance of the tested columns. From the application of the 500°C isotherm method, proposed in EN1992-1-2, it can be noticed that this method led to smaller values of the fire resistance than those obtained in the experimental tests. The tabulated data method A, proposed in EN1992-1-2, proved to be very conservative.
Article navigation
1 December 2011
Research Article|
December 01 2011
Fire Behaviour of Concrete Columns with Restrained Thermal Elongation
Alberto Martins;
Alberto Martins
1
Department of Civil Engineering, Faculty of Sciences and Technology, University of Coimbra, Portugal
Search for other works by this author on:
João Rodrigues
João Rodrigues
1
Department of Civil Engineering, Faculty of Sciences and Technology, University of Coimbra, Portugal
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 2040-2325
Print ISSN: 2040-2317
Journal of Structural Fire Engineering (2011) 2 (4): 319–332.
Citation
Martins A, Rodrigues J (2011), "Fire Behaviour of Concrete Columns with Restrained Thermal Elongation". Journal of Structural Fire Engineering, Vol. 2 No. 4 pp. 319–332, doi: https://doi.org/10.1260/2040-2317.2.4.319
Download citation file:
New and popular articles
Suggested Reading
EN1992 Eurocode 2: Design of concrete structures
Proceedings of the Institution of Civil Engineers - Civil Engineering (November,2001)
Influence of material properties on the elongation of tendons
Proceedings of the Institution of Civil Engineers - Structures and Buildings (June,2015)
Prospects in elongation of railway transition curves
Proceedings of the Institution of Civil Engineers - Transport (January,2018)
Eurocodes—the new environment for structural design
Proceedings of the Institution of Civil Engineers - Civil Engineering (November,2001)
Thermal elongation of sandwich panels
Proceedings of the Institution of Civil Engineers - Structures and Buildings (March,2013)
Related Chapters
Chapter 1 Eurocode 1 Actions on structures: Part 1.2: General Actions Actions on structures exposed to fire
Designers' Guide to Eurocode 1: Actions on Buildings: EN1991-1-1 and -1-3 TO -1-7
17.7 References
ICE manual of structural design: buildings
11.6 References
ICE manual of structural design: buildings
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.