A numerical model was developed for tracing the behavior of circular reinforced concrete (RC) columns over the entire range of loading from pre-fire conditions to collapse under fire. The macroscopic finite element based model utilizes time dependant moment-curvature relations of various column segments and the analysis is carried out in three stages; namely, establishing fire temperatures, calculating the heat transfer through the structure, and then carrying out strength analysis. The model, which accounts for high temperature nonlinear material properties, is capable of predicting the fire resistance of circular RC columns under realistic fire scenarios, loading conditions, and failure criteria. The validity of the model is established by comparing predictions from the computer program with results from full-scale fire resistance tests. The validated model is applied to undertake a set of parametric studies to quantify the effect of column size, load level, load eccentricity, and concrete strength on the fire resistance of RC columns. Results generated from parametric studies are utilized to develop a simplified equation for evaluating the fire resistance of circular RC columns. Fire resistance predictions from the proposed equation are in good agreement with those obtained from fire tests and nonlinear finite element analysis.
Article navigation
1 March 2012
Research Article|
March 01 2012
Behavior of Circular Reinforced Concrete Columns Under Fire Conditions Available to Purchase
Nikhil Raut;
Nikhil Raut
1
Civil and Environmental Engineering, Michigan State University
Search for other works by this author on:
Venkatesh Kodur
Venkatesh Kodur
1
Civil and Environmental Engineering, Michigan State University
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 2040-2325
Print ISSN: 2040-2317
Journal of Structural Fire Engineering (2012) 3 (1): 37–56.
Citation
Raut N, Kodur V (2012), "Behavior of Circular Reinforced Concrete Columns Under Fire Conditions". Journal of Structural Fire Engineering, Vol. 3 No. 1 pp. 37–56, doi: https://doi.org/10.1260/2040-2317.3.1.37
Download citation file:
Suggested Reading
Extension of the Zone Method of Eurocode 2 for reinforced concrete columns subjected to standard fire
Journal of Structural Fire Engineering (June,2016)
Extension of the zone method for the design of circular and tubular concrete columns subjected to a standard fire
Journal of Structural Fire Engineering (September,2023)
Improving ductility of non-seismically designed RC columns
Proceedings of the Institution of Civil Engineers - Structures and Buildings (February,2005)
BRE defends timber frame
Structural Survey (December,2002)
Nonlinear analysis of Reinforced Concrete Columns with Fiber Reinforced Polymer Bars
World Journal of Engineering (December,2011)
Related Chapters
Training of ANN using Mountain Gazelle Optimizer for fire resistance of FRP-strengthened beams
Machine Learning in Civil Engineering and Infrastructure Development: A Practitioner's Handbook
RESIDUAL PROPERTIES OF HYBRID POLYPROPYLENE-STEEL FIBRE REINFORCED HPC EXPOSED TO HIGH TEMPERATURES
Application of Codes, Design and Regulations: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–7 July 2005
HEAT-RESISTANT CELLULAR CONCRETES BASED ON ALKALINE CEMENTS
Use of Foamed Concrete in Construction: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5 July 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.