This paper presents the details of full scale fire tests of LSF wall panels conducted using realistic fire time-temperature curves. Tests included eight LSF wall specimens of various configurations exposed to both parametric design and natural fire curves. Details of the fire test set-up, test procedure and the results including the measured time-temperature and deformation curves of LSF wall panels are presented along with wall stud failure modes and times. This paper also compares the structural and thermal behavioural characteristics of LSF wall studs with those based on the standard time-temperature curve. Finally, the stud failure times and temperatures are summarized for both standard and realistic design fire curves. This study provides the necessary test data to validate the numerical models of LSF wall panels and to undertake a detailed study into the structural and thermal performance of LSF wall panels exposed to realistic design fire curves.
Article navigation
1 December 2014
Research Article|
December 01 2014
Experimental Study of Load-Bearing Cold-Formed Steel Walls Exposed to Realistic Design Fires
Anthony Ariyanayagam;
Anthony Ariyanayagam
1
School of Civil Engineering and Built Environment, Science and Engineering Faculty, Queensland University of Technology, Brisbane, QLD 4000, Australia
Search for other works by this author on:
Mahen Mahendran
Mahen Mahendran
1
School of Civil Engineering and Built Environment, Science and Engineering Faculty, Queensland University of Technology, Brisbane, QLD 4000, Australia
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 2040-2325
Print ISSN: 2040-2317
Journal of Structural Fire Engineering (2014) 5 (4): 291–330.
Citation
Ariyanayagam A, Mahendran M (2014), "Experimental Study of Load-Bearing Cold-Formed Steel Walls Exposed to Realistic Design Fires". Journal of Structural Fire Engineering, Vol. 5 No. 4 pp. 291–330, doi: https://doi.org/10.1260/2040-2317.5.4.291
Download citation file:
Suggested Reading
Effectiveness of damaged fireproofing in structural steel members subjected to fire
Journal of Structural Fire Engineering (February,2019)
Fire performance of LSF wall panels exposed to fire on both surfaces: a numerical approach
Journal of Structural Fire Engineering (April,2026)
Results and analysis of a large-scale fire test on a multi-bay composite steel-frame floor system
Journal of Structural Fire Engineering (March,2016)
Fire resistance of extruded hollow-core slabs
Journal of Structural Fire Engineering (July,2017)
Comparison of fire resistance of damaged fireproofed steel beams under hydrocarbon pool fire and ASTM E119 fire exposure
Journal of Structural Fire Engineering (January,2019)
Recommended for you