Article navigation
Purpose

This paper aims to understand the structural fire performance of two-way post-tensioned flat slabs, particularly their deformations and load-carrying mechanisms in fire, and to explore the behaviour of post-tensioned high-strength self-compacting concrete flat slabs with unbonded tendons in fire.

Design/methodology/approach

Four tests of post-tensioned high-strength self-compacting concrete flat slabs were conducted under fire conditions. Numerical modelling using the commercial package ABAQUS was conducted to help interpret the test results.

Findings

Two of the specimens with lower moisture contents demonstrated excellent fire resistance performance, while the others with slightly higher moisture contents experienced severe concrete spalling.

Originality/value

The test results were discussed in respect of thermal profiles, deflections, crack patterns and concrete spalling. The performance of post-tensioned high-strength self-compacting concrete flat slabs with unbonded tendons under fire conditions was better understood.