Purpose

The purpose of this paper is to evaluate high strength concrete (HSC) containing polypropylene fibers (PP-fibers) at high temperature under a compressive load.

Design/methodology/approach

The use of PP fibers in HSC is known to reduce and at times eliminate the risk of spalling. HSC containing 0, 1 and 2 kg/m3 of PP-fibers were subjected to various temperatures from 20°C to 150°C, 300°C and 450°C and evaluated in a “hot condition”. One group of specimens was in a non-stressed condition during heating (unstressed hot), while a second group was subjected to an initial preload of 40 per cent of the room temperature compressive strength during the heating (stressed hot).

Findings

Results showed that stressed concrete containing PP-fibers had lower thermal gradients (the temperature difference between the surface and center temperatures as a function of radial distance) and a decrease in relative porosity. However, the compressive strength of stressed specimens was improved with or without fibers as compared to that of the unstressed HSC. The increased stress levels due to concrete expansion at elevated temperature were also reported. The PP-fibers did not have a significant effect on the compressive strength of stressed concrete as compared to the unstressed state.

Originality/value

This paper reports the compressive strength of PP-fibers in HSC at elevated temperature with and without a pre-load.

Licensed re-use rights only
You do not currently have access to this content.
Don't already have an account? Register

Purchased this content as a guest? Enter your email address to restore access.

Please enter valid email address.
Email address must be 94 characters or fewer.
Pay-Per-View Access
$41.00
Rental

or Create an Account

Close Modal
Close Modal