The tuned mass damper is a passive control technique, which is used in high-rise building structures for mitigation of the vibration produced as a result of wind and earthquake loadings. Irregularity in structure increases the chances of vibrations produced from these loadings. In this paper, detailed experimental work was carried out for vibration mitigation of an irregular four-storey structure having mass irregularity at its fourth floor using a single tuned mass damper (STMD) and multiple tuned mass dampers (MTMDs), against different harmonic and seismic loadings; such work has never been carried out before. The positions of STMD and MTMDs were varied along each floor and all possible configurations of STMD and MTMDs were tested against these loadings. For comparison, the acceleration responses of each storey for all configurations of STMD and MTMDs were compared with that of the uncontrolled structure. It was found that under all types of loadings, the STMD reduces the acceleration response of all floors of the uncontrolled structure; similarly, all configurations of MTMDs show further reduction in acceleration response, demonstrating the efficiency of MTMDs over a STMD in irregular structures.
Article navigation
1 October 2023
Research Article|
July 06 2021
Vibration control of an irregular structure using single and multiple tuned mass dampers
Imdad Ullah Khan, MS
;
Imdad Ullah Khan, MS
PhD student, Sungkyunkwan university, Seoul, South Korea
Search for other works by this author on:
Muhammad Usman, PhD;
Muhammad Usman, PhD
Associate Professor, School of Civil & Environmental Engineering, National University of Sciences and Technology (NUST), Islamabad, Pakistan (corresponding author: m.usman@nice.nust.edu.pk, m.usman@kaist.ac.kr)
Search for other works by this author on:
Muhammad Tanveer, MS
Muhammad Tanveer, MS
PhD student, University of Seoul, Seoul, South Korea
Search for other works by this author on:
Publisher: Emerald Publishing
Received:
May 21 2021
Accepted:
May 21 2021
Online ISSN: 1751-7702
Print ISSN: 0965-0911
Emerald Publishing Limited: All rights reserved
2021
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2023) 176 (10): 778–790.
Article history
Received:
May 21 2021
Accepted:
May 21 2021
Citation
Khan IU, Usman M, Tanveer M (2023), "Vibration control of an irregular structure using single and multiple tuned mass dampers". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 176 No. 10 pp. 778–790, doi: https://doi.org/10.1680/jstbu.21.00011
Download citation file:
New and popular articles
Suggested Reading
Hybrid seismic control of buildings using tuned mass and magnetorheological dampers
Proceedings of the Institution of Civil Engineers - Structures and Buildings (April,2019)
Isolated soil mass at foundation for mitigating seismic risk
Geotechnical Research (May,2016)
Reliability-based design of tuned-mass dampers with soil−structure interaction
Proceedings of the Institution of Civil Engineers - Engineering and Computational Mechanics (May,2019)
Analysis of the seismic performance of a two-storey log house
Proceedings of the Institution of Civil Engineers - Structures and Buildings (November,2015)
Correlation of a new index with energy-based damage indices
Proceedings of the Institution of Civil Engineers - Structures and Buildings (September,2016)
Related Chapters
Vulnerability
Landslide Risk Assessment
The ground as a hazard
ICE Manual of Geotechnical Engineering, Second edition, Volume I
Chapter 11 Controlling exposure to chemical hazards
ICE manual of health and safety in construction
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.