Current fire design to the Eurocodes allows the effective length of concrete-filled steel hollow-section columns, in braced multistorey buildings, to be taken as 0·7 or 0·5 times the system length of the column, depending on whether the column is continuous at one or both ends. In the case where the column is continuous at both ends, numerical analyses presented in this paper show that, provided local buckling does not occur, an effective length of 0·55 can be assumed. However, observations from tests on isolated members suggest that local buckling generally occurs at the top of heated concrete-filled columns. This is caused by differential thermal expansion, where the expansion of the steel shell is greater than that of the concrete core. This differential expansion causes the steel shell to support the applied load, which, due to loss of strength as its temperature rises, will buckle locally, with the load being redirected back to the concrete core. The analyses showed that if the effects of local buckling were included, the effective length of columns in fire was increased to a value of 0·75. It is recommended that this value should be used in design. Analyses were also conducted on columns that were continuous at one end. These indicated that a value of 0·8 times the system length should be used in design, if the column is continuous at its base. If an idealized-pinned foundation is assumed, the effective length should be taken as the system length.
Article navigation
May 2000
Research Article|
May 01 2000
Effective lengths of concrete-filled steel square hollow sections in fire Available to Purchase
Colin Bailey, BEng, PhD
Colin Bailey, BEng, PhD
Senior Research Engineer
Building Research Establishment
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 1751-7702
Print ISSN: 0965-0911
© 2000 Thomas Telford Ltd
2000
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2000) 140 (2): 169–178.
Citation
Bailey C (2000), "Effective lengths of concrete-filled steel square hollow sections in fire". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 140 No. 2 pp. 169–178, doi: https://doi.org/10.1680/stbu.2000.140.2.169
Download citation file:
Suggested Reading
Thermo-mechanically loaded glass-fibre-reinforced polymer single-bolt single-lap joints
Proceedings of the Institution of Civil Engineers - Structures and Buildings (May,2017)
Thermal elongation of sandwich panels
Proceedings of the Institution of Civil Engineers - Structures and Buildings (March,2013)
Thermoelastic restrained buckling of composite beams
Proceedings of the Institution of Civil Engineers - Engineering and Computational Mechanics (June,2009)
Structural assessment of composite seam-welded rectangular hollow columns
Proceedings of the Institution of Civil Engineers - Structures and Buildings (May,2017)
Load-bearing capacity of axially loaded circular concrete-filled steel tubular columns
Proceedings of the Institution of Civil Engineers - Structures and Buildings (December,2015)
Related Chapters
Moorgate Shaft Base Slab, design, detailing and construction
Crossrail Project: Infrastructure design and construction
Behaviour of Rectangular Rc Columns Retrofitted by Fibre Reinforced Polymers Under Axial and Cyclic Loading
Role of Concrete Bridges in Sustainable Development: Proceedings of the International Symposium held at the University of Dundee, Scotland, UK on 3–4 September 2003
USE OF COMPOSITE STRUCTURES IN A BUILDING ABOVE A METRO STATION
Innovations and Developments In Concrete Materials And Construction: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 9–11 September 2002
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.