Carbon-fibre-reinforced polymer (CFRP) tendons can be used as a corrosion-resistant alternative to steel for reinforcing or prestressing concrete in aggressive marine environments. The design lives of many civil marine structures often span decades and so the long-term durability of the internal reinforcement is important. One significant, yet overlooked, aspect of CFRP tendon durability is its susceptibility to swell on absorption of aqueous solutions including water and salt water. This paper reviews uptake-induced swelling in CFRP materials and draws comparisons with studies of swelling caused by thermal effects. The diffusion of aqueous solutions and their interaction with the polymer matrix are identified as the primary mechanisms responsible for the swelling. Experimental details are presented that correlate the uptake of water and salt water to swelling observed in CFRP tendons. The results are contrasted with both uptake- and thermal-driven behaviour cited in the literature. Lamé's equations are used to estimate the magnitude of the resulting stresses induced in the surrounding concrete. The practical significance of the findings is discussed, including the potential for cracking in the surrounding concrete cover and the implications for the tendon–concrete bond.
Article navigation
August 2009
Research Article|
August 01 2009
Uptake swelling and thermal expansion of CFRP tendons
P. Scott, MEng;
P. Scott, MEng
PhD candidate
Department of Engineering, University of Cambridge, UK
Search for other works by this author on:
J. M. Lees, PhD
J. M. Lees, PhD
Senior Lecturer
Department of Engineering, University of Cambridge, UK
Search for other works by this author on:
Publisher: Emerald Publishing
Revision Received:
November 28 2008
Accepted:
April 30 2009
Online ISSN: 1751-7702
Print ISSN: 0965-0911
© 2009 Thomas Telford Ltd
2009
Proceedings of the Institution of Civil Engineers - Structures and Buildings (2009) 162 (4): 263–273.
Article history
Revision Received:
November 28 2008
Accepted:
April 30 2009
Citation
Scott P, Lees JM (2009), "Uptake swelling and thermal expansion of CFRP tendons". Proceedings of the Institution of Civil Engineers - Structures and Buildings, Vol. 162 No. 4 pp. 263–273, doi: https://doi.org/10.1680/stbu.2009.162.4.263
Download citation file:
New and popular articles
Suggested Reading
Durability and strength variation due to corrosion in RC beams using brick and stone chips
Proceedings of the Institution of Civil Engineers - Structures and Buildings (February,2021)
Littlehaven promenade and seawall, South Shields, UK
Maritime Engineering (March,2015)
Design and construction of the tower headland wave walls, Blackpool, UK
Proceedings of the Institution of Civil Engineers - Civil Engineering (November,2012)
Minikin’s equation mistake — a mystic art of systems of measuring units
Maritime Engineering (December,2024)
The adhesion strength of fibre-reinforced repair concrete under hot coastal conditions
Proceedings of the Institution of Civil Engineers - Structures and Buildings (January,2026)
Related Chapters
INTERNATIONAL DEVELOPMENTS IN THE FIELD OF AGEING MANAGEMENT OF NUCLEAR POWER INFRASTRUCTURE
Role of Concrete in Nuclear Facilities
FIELD TRIALS ON COVERCRETE MONITORING SENSORS: A TEMPERATURE CORRECTION PROTOCOL FOR CONDUCTIVITY MEASUREMENTS
Innovations and Developments In Concrete Materials And Construction: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 9–11 September 2002
CRITERIA FOR AND PREDICTION OF LIMIT STATES OF DEGRADATION OF REINFORCED CONCRETE STRUCTURES
Role of Concrete in Nuclear Facilities
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.
